Flammable liquids, Category 2
H225 Highly flammable liquid and vapour
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P233 Keep container tightly closed.
P240 Ground and bond container and receiving equipment.
P241 Use explosion-proof [electrical/ventilating/lighting/...] equipment.
P242 Use non-sparking tools.
P243 Take action to prevent static discharges.
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...
P303+P361+P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse affected areas with water [or shower].
P370+P378 In case of fire: Use ... to extinguish.
P403+P235 Store in a well-ventilated place. Keep cool.
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Fresh air, rest.
Remove contaminated clothes. Rinse and then wash skin with water and soap.
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.
Rinse mouth.
no data available
no data available
Use dry chemical, carbon dioxide or alcohol-resistant foam.
Highly flammable. Above 15.5°C explosive vapour/air mixtures may be formed.
Use carbon dioxide, dry powder, foam. In case of fire: keep drums, etc., cool by spraying with water.
Do NOT wash away into sewer. Collect leaking and spilled liquid in sealable containers as far as possible. Absorb remaining liquid in sand or inert absorbent. Then store and dispose of according to local regulations.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
NO open flames, NO sparks and NO smoking. Above 15.5°C use a closed system, ventilation and explosion-proof electrical equipment. Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Fireproof. Separated from strong oxidants, strong bases and strong acids.
TLV: 50 ppm as TWA; 150 ppm as STEL.MAK: 96 mg/m3, 20 ppm; peak limitation category: II(2); pregnancy risk group: C
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear safety spectacles or eye protection in combination with breathing protection.
Protective gloves.
Use ventilation, local exhaust or breathing protection.
no data available
Colorless liquid with a mild odor
no data available
no data available
-52°C(lit.)
96°C
no data available
no data available
15°C(lit.)
no data available
no data available
no data available
no data available
In water: insoluble
1.76
6.3 kPa(25°C)
0.862
no data available
no data available
no data available
no data available
The vapour is heavier than air and may travel along the ground; distant ignition possible.Reacts with strong acids, strong bases and strong oxidants including nitrates. This generates fire and explosion hazard. Attacks plastics.
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
The vapour is irritating to the respiratory tract. The substance is mildly irritating to the eyes and skin. Exposure far above the OEL could cause lowering of consciousness.
The substance defats the skin, which may cause dryness or cracking.
A harmful contamination of the air will be reached rather slowly on evaporation of this substance at 20°C.
no data available
no data available
no data available
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: UN1123 (For reference only, please check.)
IMDG: UN1123 (For reference only, please check.)
IATA: UN1123 (For reference only, please check.)
ADR/RID: BUTYL ACETATES (For reference only, please check.)
IMDG: BUTYL ACETATES (For reference only, please check.)
IATA: BUTYL ACETATES (For reference only, please check.)
ADR/RID: 3 (For reference only, please check.)
IMDG: 3 (For reference only, please check.)
IATA: 3 (For reference only, please check.)
ADR/RID: II (For reference only, please check.)
IMDG: II (For reference only, please check.)
IATA: II (For reference only, please check.)
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available