Flammable liquids, Category 2
Skin irritation, Category 2
Skin sensitization, Sub-category 1B
H225 Highly flammable liquid and vapour
H315 Causes skin irritation
H317 May cause an allergic skin reaction
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P233 Keep container tightly closed.
P240 Ground and bond container and receiving equipment.
P241 Use explosion-proof [electrical/ventilating/lighting/...] equipment.
P242 Use non-sparking tools.
P243 Take action to prevent static discharges.
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...
P264 Wash ... thoroughly after handling.
P261 Avoid breathing dust/fume/gas/mist/vapours/spray.
P272 Contaminated work clothing should not be allowed out of the workplace.
P303+P361+P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse affected areas with water [or shower].
P370+P378 In case of fire: Use ... to extinguish.
P302+P352 IF ON SKIN: Wash with plenty of water/...
P321 Specific treatment (see ... on this label).
P332+P317 If skin irritation occurs: Get medical help.
P362+P364 Take off contaminated clothing and wash it before reuse.
P333+P317 If skin irritation or rash occurs: Get medical help.
P403+P235 Store in a well-ventilated place. Keep cool.
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
Excerpt from ERG Guide 127P [Flammable Liquids (Water-Miscible)]: Inhalation or contact with material may irritate or burn skin and eyes. Fire may produce irritating, corrosive and/or toxic gases. Vapors may cause dizziness or suffocation. Runoff from fire control may cause pollution. (ERG, 2016)
Basic treatment: Establish a patent airway. Suction if necessary. Watch for signs of respiratory insufficiency and assist ventilations if necessary. Administer oxygen by nonrebreather mask at 10 to 15 L/min. Provide a low-stimulus environment. Monitor for shock and treat if necessary . Anticipate seizures and treat if necessary . For eye contamination, flush eyes immediately with water. Irrigate each eye continuously with normal saline during transport . Do not use emetics. For ingestion, rinse mouth and administer 5 mL/kg up to 200 mL of water for dilution if the patient can swallow, has a strong gag reflex, and does not drool . Treat frostbite by rapid rewarming . Ethers and related compounds
Water may be ineffective ... alcohol foam is recommended . From table
Excerpt from ERG Guide 127P [Flammable Liquids (Water-Miscible)]: HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers. Those substances designated with a (P) may polymerize explosively when heated or involved in a fire. Runoff to sewer may create fire or explosion hazard. Containers may explode when heated. Many liquids are lighter than water. (ERG, 2016)
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Store the container tightly closed in a dry, cool and well-ventilated place. Store apart from foodstuff containers or incompatible materials.
Component | Butyl vinyl ether | |||
---|---|---|---|---|
CAS No. | 111-34-2 | |||
Limit value - Eight hours | Limit value - Short term | |||
ppm | mg/m3 | ppm | mg/m3 | |
Latvia | ? | 20 | ? | ? |
Remarks |
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
Liquid. Liquid.
Clear, colourless.
no data available
-91.4 °C. Remarks:CV ±0.1 °C.
94.49 °C. Atm. press.:1 013.25 hPa. Remarks:Extrapolated value from vapour pressure curve using the Antoine equation.
no data available
no data available
-6 °C. Atm. press.:1 013.25 hPa.
190 °C. Atm. press.:1 013.25 hPa.
no data available
no data available
dynamic viscosity (in mPa s) = 0.44. Temperature:20°C. Remarks:Calculated with a density of the test item of p = 0.7789 g/cm3.;kinematic viscosity (in mm2/s) = 0.57. Temperature:20°C.;dynamic viscosity (in mPa s) = 0.34. Temperature:40°C. Remarks:Calculated with a density of the test item of p = 0.7588 g/cm3.
Insoluble in water
Pow = 1 426. Temperature:20 °C. Remarks:SD: 293; mean of six replicates.;log Pow = 3.15. Temperature:20 °C. Remarks:SD: 0.09, mean of six replicates.
53.65 hPa. Temperature:20 °C. Remarks:Interpolated value from vapour pressure curve using the Antoine equation.;69.24 hPa. Temperature:25 °C. Remarks:Interpolated value from vapour pressure curve using the Antoine equation.;214.23 hPa. Temperature:50 °C. Remarks:Interpolated value from vapour pressure curve using the Antoine equation.
0.789. Temperature:20 °C.
3.5 (vs air)
no data available
Highly flammable. Slightly soluble in water. Ethers tend to form unstable peroxides when exposed to oxygen. Ethyl, isobutyl, ethyl tert-butyl, and ethyl tert-pentyl ether are particularly hazardous in this respect. Ether peroxides can sometimes be observed as clear crystals deposited on containers or along the surface of the liquid.
no data available
Flammable, dangerous fire risk.Ethers, such as BUTYL VINYL ETHER can act as bases. They form salts with strong acids and addition complexes with Lewis acids. The complex between diethyl ether and boron trifluoride is an example. Ethers may react violently with strong oxidizing agents. In other reactions, which typically involve the breaking of the carbon-oxygen bond, ethers are relatively inert.
no data available
Can react with oxidizing materials.
When heated to decomposition it emits acrid smoke and irritating fumes.
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
An estimated BCF of 7 was calculated for butyl vinyl ether(SRC), using a water solubility of 3,000 mg/l(1) and a regression-derived equation(2). According to a classification scheme(3), this BCF suggests the potential for bioconcentration in aquatic organisms is low.
The Koc of butyl vinyl ether is estimated as approximately 53(SRC), using a water solubility of 3,000 mg/l(1) and a regression-derived equation(2,SRC). According to a classification scheme(3), this estimated Koc value suggests that butyl vinyl ether is expected to have very high mobility in soil(SRC).
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: UN2352 (For reference only, please check.)
IMDG: UN2352 (For reference only, please check.)
IATA: UN2352 (For reference only, please check.)
ADR/RID: BUTYL VINYL ETHER, STABILIZED (For reference only, please check.)
IMDG: BUTYL VINYL ETHER, STABILIZED (For reference only, please check.)
IATA: BUTYL VINYL ETHER, STABILIZED (For reference only, please check.)
ADR/RID: 3 (For reference only, please check.)
IMDG: 3 (For reference only, please check.)
IATA: 3 (For reference only, please check.)
ADR/RID: II (For reference only, please check.)
IMDG: II (For reference only, please check.)
IATA: II (For reference only, please check.)
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available