no data available
no data available
no data available
no data available
no data available
no data available
no data available
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
SYMPTOMS: This compound may cause nausea, vomiting, headache, diarrhea, bladder tumors, and depression of bone marrow function. It may also cause severe local irritation of eyes, skin and other tissues. ACUTE/CHRONIC HAZARDS: This compound is a skin, eye and mucous membrane irritant. It is toxic by ingestion, inhalation and skin absorption. (NTP, 1992)
no data available
Fires involving this compound should be controlled using a dry chemical, carbon dioxide or Halon extinguisher. (NTP, 1992)
Flash point data are not available for this chemical, but it is probably combustible. (NTP, 1992)
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
PRECAUTIONS FOR "CARCINOGENS": A high-efficiency particulate arrestor (HEPA) or charcoal filters can be used to minimize amt of carcinogen in exhausted air ventilated safety cabinets, lab hoods, glove boxes or animal rooms ... Filter housing that is designed so that used filters can be transferred into plastic bag without contaminating maintenance staff is avail commercially. Filters should be placed in plastic bags immediately after removal ... The plastic bag should be sealed immediately ... The sealed bag should be labelled properly ... Waste liquids ... should be placed or collected in proper containers for disposal. The lid should be secured & the bottles properly labelled. Once filled, bottles should be placed in plastic bag, so that outer surface ... is not contaminated ... The plastic bag should also be sealed & labelled. ... Broken glassware ... should be decontaminated by solvent extraction, by chemical destruction, or in specially designed incinerators. Chemical Carcinogens
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
PRECAUTIONS FOR "CARCINOGENS": Storage site should be as close as practicable to lab in which carcinogens are to be used, so that only small quantities required for ... expt need to be carried. Carcinogens should be kept in only one section of cupboard, an explosion-proof refrigerator or freezer (depending on chemicophysical properties ...) that bears appropriate label. An inventory ... should be kept, showing quantity of carcinogen & date it was acquired ... Facilities for dispensing ... should be contiguous to storage area. Chemical Carcinogens
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
PHYSICAL DESCRIPTION: Colorless plates or brown solid. (NTP, 1992)
PLATELETS FROM PETROLEUM ETHER
no data available
129 to 133° F (NTP, 1992)
414.3°C at 760 mmHg
no data available
no data available
204.4°C
no data available
no data available
no data available
no data available
less than 1 mg/mL at 72° F (NTP, 1992)
log Kow = 4.535 (est)
4.49E-07mmHg at 25°C
1.234g/cm3
no data available
no data available
no data available
no data available
CHLORNAPHAZINE reacts with nucleophiles (NTP, 1992).
no data available
no data available
no data available
no data available
no data available
no data available
no data available
Classification of carcinogenicity: 1) evidence in humans: sufficient; 2) evidence in animals: limited. Overall summary evaluation of carcinogenic risk to humans is Group 1: The agent is carcinogenic to humans. From table
no data available
no data available
no data available
no data available
no data available
Based upon an estimated Log Kow of 4.535(1), the BCF for chlornaphazine can be estimated to be about 1650 from a recommended regression-derived equation(2,SRC). This BCF value suggests that bioconcentration in aquatic organisms may be important(SRC).
Based upon an estimated log Kow of 4.535(1), the Koc for chlornaphazine can be estimated to be about 21000 from a regression-derived equation developed for aromatic and polyaromatic compounds(2,SRC). This Koc value suggests that chlornaphazine may be essentially immobile in soil(3).
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available