Flammable liquids, Category 3
H226 Flammable liquid and vapour
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P233 Keep container tightly closed.
P240 Ground and bond container and receiving equipment.
P241 Use explosion-proof [electrical/ventilating/lighting/...] equipment.
P242 Use non-sparking tools.
P243 Take action to prevent static discharges.
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...
P303+P361+P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse affected areas with water [or shower].
P370+P378 In case of fire: Use ... to extinguish.
P403+P235 Store in a well-ventilated place. Keep cool.
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Fresh air, rest.
Remove contaminated clothes. Rinse skin with plenty of water or shower. Refer for medical attention .
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.
Rinse mouth. Refer for medical attention .
no data available
no data available
Use dry chemical, carbon dioxide or alcohol-resistant foam.
Flammable. Gives off irritating or toxic fumes (or gases) in a fire. Above 54°C explosive vapour/air mixtures may be formed.
Use powder, foam, carbon dioxide. NO hydrous agents. NO water. In case of fire: keep drums, etc., cool by spraying with water. NO direct contact with water.
Personal protection: filter respirator for organic gases and vapours adapted to the airborne concentration of the substance. Ventilation. Collect leaking and spilled liquid in sealable containers as far as possible. Absorb remaining liquid in sand or inert absorbent. Then store and dispose of according to local regulations.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
NO open flames, NO sparks and NO smoking. Above 54°C use a closed system, ventilation and explosion-proof electrical equipment. Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Fireproof. Dry. Separated from acids and strong oxidants. See Chemical Dangers.
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear safety spectacles.
Protective gloves.
Use ventilation.
no data available
clear liquid
no data available
no data available
-112°C
156°C
no data available
no data available
52°C
no data available
no data available
no data available
no data available
In water: slightly soluble
no data available
3.19mmHg at 25°C
0.969
no data available
no data available
no data available
no data available
Decomposes on heating and on burning. This produces toxic fumes including phosphorus oxides. Reacts with water, acids and strong oxidants. This generates fire and explosion hazard.
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
The substance and the vapour are irritating to the eyes and skin.
no data available
No indication can be given about the rate at which a harmful concentration of this substance in the air is reached on evaporation at 20°C.
no data available
no data available
no data available
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: UN2323 (For reference only, please check.)
IMDG: UN2323 (For reference only, please check.)
IATA: UN2323 (For reference only, please check.)
ADR/RID: TRIETHYL PHOSPHITE (For reference only, please check.)
IMDG: TRIETHYL PHOSPHITE (For reference only, please check.)
IATA: TRIETHYL PHOSPHITE (For reference only, please check.)
ADR/RID: 3 (For reference only, please check.)
IMDG: 3 (For reference only, please check.)
IATA: 3 (For reference only, please check.)
ADR/RID: III (For reference only, please check.)
IMDG: III (For reference only, please check.)
IATA: III (For reference only, please check.)
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available
Explosive limits are unknown in literature, although the substance is combustible and has a flash point < 61°C.Do NOT use in the vicinity of a fire or a hot surface, or during welding.