Not classified.
none
none
none
none
none
no data available
Fresh air, rest.
Rinse and then wash skin with water and soap.
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.
Rinse mouth.
no data available
no data available
Use dry chemical, carbon dioxide or alcohol-resistant foam.
Combustible.
Use special powder, dry sand. NO other agents.
Personal protection: particulate filter respirator adapted to the airborne concentration of the substance. Sweep spilled substance into covered containers. If appropriate, moisten first to prevent dusting.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
NO open flames. Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Separated from strong oxidants.
TLV: (as Sn): 2 mg/m3, as TWA.EU-OEL: 2 mg/m3 as TWA
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear safety goggles.
Protective gloves.
Use local exhaust or breathing protection.
no data available
Solid. Powder.
Grey (metallic).
no data available
231.91 °C.
2 507 °C. Remarks:No further data on results available.
no data available
no data available
2270°C
> 400 °C. Remarks:After heating, the cube contained a grey solid.
no data available
no data available
no data available
In water: < 4 μg/L. Temperature:20 °C. pH:>= 6.5 - <= 7.7.
no data available
0.008 mm Hg. Temperature:1 224 °C. Remarks:No further data available.
7.26 g/cm3.;5.77 g/cm3.
no data available
no data available
no data available
no data available
Reacts with strong oxidants.
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
May cause mechanical irritation to the respiratory tract.
The substance may have effects on the lungs. This may result in a benign pneumoconiosis (stannosis).
A harmful concentration of airborne particles can be reached quickly , especially if powdered.
no data available
no data available
no data available
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available