Hazardous to the aquatic environment, short-term (Acute) - Category Acute 1
Hazardous to the aquatic environment, long-term (Chronic) - Category Chronic 2
H400 Very toxic to aquatic life
H411 Toxic to aquatic life with long lasting effects
P273 Avoid release to the environment.
P391 Collect spillage.
none
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Fresh air, rest. Refer for medical attention.
Remove contaminated clothes. Rinse and then wash skin with water and soap.
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.
Rinse mouth. Refer for medical attention .
no data available
no data available
Use dry chemical, carbon dioxide or alcohol-resistant foam.
Combustible.
Use water spray, powder, foam, carbon dioxide.
Personal protection: particulate filter respirator adapted to the airborne concentration of the substance. Do NOT let this chemical enter the environment. Sweep spilled substance into covered containers. If appropriate, moisten first to prevent dusting. Carefully collect remainder. Then store and dispose of according to local regulations.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
NO open flames. Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Store in an area without drain or sewer access. Provision to contain effluent from fire extinguishing.
TLV: 3 mg/m3, as TWA; A4 (not classifiable as a human carcinogen)
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear safety spectacles.
Protective gloves.
Use local exhaust or breathing protection.
no data available
Solid.
no data available
no data available
49.5 - 50 °C.
414 °C. Atm. press.:760 Torr.
no data available
no data available
220 °C.
no data available
no data available
no data available
cSt = 11. Temperature:50.0°C. Remarks:Kinematic viscosity.;cSt = 9.9. Temperature:55.0°C. Remarks:Kinematic viscosity.
In water: 1.9 mg/L. Temperature:20 °C. Remarks:PH not reported.
log Pow = 4.63. Temperature:20 °C. Remarks:PH not reported.
0.001 Pa. Temperature:25 °C. Remarks:6.4 E-06 torr.;0.004 Pa. Temperature:40 °C. Remarks:3.1 E-05 torr.;0.027 Pa. Temperature:60 °C. Remarks:2.0 E-04 torr.
1.21 g/cm3. Temperature:50 °C.
no data available
no data available
no data available
no data available
Decomposes on heating. This produces toxic fumes.
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
The substance may have effects on the peripheral nervous system. This may result in impaired functions.
Evaporation at 20°C is negligible; a harmful concentration of airborne particles can, however, be reached quickly on spraying or when dispersed, especially if powdered.
no data available
no data available
no data available
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Yes
IMDG: Yes
IATA: Yes
no data available
no data available