Acute toxicity - Category 2, Oral
Acute toxicity - Category 2, Dermal
Acute toxicity - Category 1, Inhalation
Hazardous to the aquatic environment, short-term (Acute) - Category Acute 1
H300 Fatal if swallowed
H310 Fatal in contact with skin
H330 Fatal if inhaled
H400 Very toxic to aquatic life
P264 Wash ... thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P262 Do not get in eyes, on skin, or on clothing.
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...
P260 Do not breathe dust/fume/gas/mist/vapours/spray.
P271 Use only outdoors or in a well-ventilated area.
P284 [In case of inadequate ventilation] wear respiratory protection.
P273 Avoid release to the environment.
P301+P316 IF SWALLOWED: Get emergency medical help immediately.
P321 Specific treatment (see ... on this label).
P330 Rinse mouth.
P302+P352 IF ON SKIN: Wash with plenty of water/...
P316 Get emergency medical help immediately.
P361+P364 Take off immediately all contaminated clothing and wash it before reuse.
P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P320 Specific treatment is urgent (see ... on this label).
P391 Collect spillage.
P405 Store locked up.
P403+P233 Store in a well-ventilated place. Keep container tightly closed.
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Fresh air, rest. Refer immediately for medical attention.
Wear protective gloves when administering first aid. Remove contaminated clothes. Rinse and then wash skin with water and soap. Refer immediately for medical attention.
Rinse with plenty of water (remove contact lenses if easily possible). Refer for medical attention.
Rest. Rinse mouth. Refer immediately for medical attention.
no data available
no data available
Use dry chemical, carbon dioxide or alcohol-resistant foam.
Combustible. Gives off irritating or toxic fumes (or gases) in a fire.
In case of fire in the surroundings: all extinguishing agents allowed.
Personal protection: complete protective clothing and face shield. Do NOT let this chemical enter the environment. Collect leaking liquid in covered containers. Store and dispose of according to local regulations.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
NO open flames. Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Separated from food and feedstuffs. Store in an area without drain or sewer access. Provision to contain effluent from fire extinguishing.
TLV BEI issued
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear face shield in combination with breathing protection.
Protective gloves. Protective clothing.
Use local exhaust.
no data available
AMBER OR BROWN LIQUID.
no data available
no data available
no data available
358.6°C at 760mmHg
no data available
no data available
170.6°C
no data available
no data available
no data available
no data available
Solubility in water at 20°C: very poor
4.2
0.04 Pa(negligible)(20°C)
1.146g/cm3
no data available
no data available
no data available
no data available
On combustion, forms toxic and irritating fumes.
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
Cholinesterase inhibition. The substance may cause effects on nervous system.
Cholinesterase inhibition. This may result in nervous system impairment.
A harmful contamination of the air will not or will only very slowly be reached on evaporation of this substance at 20°C.
no data available
no data available
no data available
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: UN2810 (For reference only, please check.)
IMDG: UN2810 (For reference only, please check.)
IATA: UN2810 (For reference only, please check.)
ADR/RID: TOXIC LIQUID, ORGANIC, N.O.S. (For reference only, please check.)
IMDG: TOXIC LIQUID, ORGANIC, N.O.S. (For reference only, please check.)
IATA: TOXIC LIQUID, ORGANIC, N.O.S. (For reference only, please check.)
ADR/RID: 6.1 (For reference only, please check.)
IMDG: 6.1 (For reference only, please check.)
IATA: 6.1 (For reference only, please check.)
ADR/RID: I (For reference only, please check.)
IMDG: I (For reference only, please check.)
IATA: I (For reference only, please check.)
ADR/RID: Yes
IMDG: Yes
IATA: Yes
no data available
no data available
Do NOT take working clothes home.Depending on the degree of exposure, periodic medical examination is suggested.Specific treatment is necessary in case of poisoning with this substance; the appropriate means with instructions must be available.If the substance is formulated with solvents also consult the ICSCs of these materials.Carrier solvents used in commercial formulations may change physical and toxicological properties.