Skin corrosion, Sub-category 1B
Specific target organ toxicity – single exposure, Category 3
Hazardous to the aquatic environment, short-term (Acute) - Category Acute 1
H314 Causes severe skin burns and eye damage
H335 May cause respiratory irritation
H400 Very toxic to aquatic life
P260 Do not breathe dust/fume/gas/mist/vapours/spray.
P264 Wash ... thoroughly after handling.
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...
P261 Avoid breathing dust/fume/gas/mist/vapours/spray.
P271 Use only outdoors or in a well-ventilated area.
P273 Avoid release to the environment.
P301+P330+P331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
P363 Wash contaminated clothing before reuse.
P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P316 Get emergency medical help immediately.
P321 Specific treatment (see ... on this label).
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P319 Get medical help if you feel unwell.
P391 Collect spillage.
P405 Store locked up.
P403+P233 Store in a well-ventilated place. Keep container tightly closed.
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Fresh air, rest. Half-upright position. Artificial respiration may be needed. Refer immediately for medical attention.
First rinse with plenty of water for at least 15 minutes, then remove contaminated clothes and rinse again. Refer for medical attention .
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.
Rinse mouth. Do NOT induce vomiting. Refer immediately for medical attention.
no data available
no data available
Use dry chemical, carbon dioxide or alcohol-resistant foam.
Not combustible. Gives off irritating or toxic fumes (or gases) in a fire. Contact with metals may evolve flammable hydrogen gas. Heating will cause rise in pressure with risk of bursting.
Use dry powder, carbon dioxide. NO water. In case of fire: keep drums, etc., cool by spraying with water. NO direct contact with water.
Personal protection: gas-tight chemical protection suit including self-contained breathing apparatus. Do NOT let this chemical enter the environment. Cover the spilled material with dry inert absorbent. Carefully collect remainder in plastic containers. Then store and dispose of according to local regulations.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Provision to contain effluent from fire extinguishing. Separated from ammonia, water, oxidants and food and feedstuffs. Cool. Dry. Well closed. Keep in a well-ventilated room. Store in an area without drain or sewer access.
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear face shield or eye protection in combination with breathing protection.
Protective gloves. Protective clothing.
Use ventilation, local exhaust or breathing protection.
no data available
Dark red liquid. Pungent chlorine odor.
no data available
no data available
-80°C
no data available
no data available
no data available
no data available
234°C
no data available
no data available
no data available
Solubility in water: reaction
no data available
25.67 psi ( 55 °C)
1.577g/cm3
3.55 (vs air)
no data available
no data available
no data available
The vapour is heavier than air.Decomposes on heating. This produces toxic and corrosive fumes including hydrogen chloride and sulfur oxides. Reacts violently with strong oxidants, acetone and ammonia. Reacts with water. This produces hydrogen chloride (see ICSC 0163). Attacks many metals in the presence of water.
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
The substance is corrosive to the eyes, skin and respiratory tract. Corrosive on ingestion. Inhalation may cause lung oedema. See Notes.
no data available
A harmful contamination of the air can be reached very quickly on evaporation of this substance at 20°C.
no data available
no data available
no data available
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: UN1828 (For reference only, please check.)
IMDG: UN1828 (For reference only, please check.)
IATA: UN1828 (For reference only, please check.)
ADR/RID: SULPHUR CHLORIDES (For reference only, please check.)
IMDG: SULPHUR CHLORIDES (For reference only, please check.)
IATA: SULPHUR CHLORIDES (For reference only, please check.)
ADR/RID: 8 (For reference only, please check.)
IMDG: 8 (For reference only, please check.)
IATA: 8 (For reference only, please check.)
ADR/RID: I (For reference only, please check.)
IMDG: I (For reference only, please check.)
IATA: I (For reference only, please check.)
ADR/RID: Yes
IMDG: Yes
IATA: Yes
no data available
no data available
Reacts violently with fire extinguishing agents such as water.The symptoms of lung oedema often do not become manifest until a few hours have passed and they are aggravated by physical effort.Rest and medical observation is therefore essential.Immediate administration of an appropriate inhalation therapy by a doctor or a person authorized by him/her, should be considered.