Flammable liquids, Category 2
H225 Highly flammable liquid and vapour
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P233 Keep container tightly closed.
P240 Ground and bond container and receiving equipment.
P241 Use explosion-proof [electrical/ventilating/lighting/...] equipment.
P242 Use non-sparking tools.
P243 Take action to prevent static discharges.
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...
P303+P361+P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse affected areas with water [or shower].
P370+P378 In case of fire: Use ... to extinguish.
P403+P235 Store in a well-ventilated place. Keep cool.
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Fresh air, rest.
Rinse skin with plenty of water or shower.
Rinse with plenty of water (remove contact lenses if easily possible).
Rinse mouth.
no data available
Immediate first aid: Ensure that adequate decontamination has been carried out. If patient is not breathing, start artificial respiration, preferably with a demand-valve resuscitator, bag-valve-mask device, or pocket mask, as trained. Perform CPR as necessary. Immediately flush contaminated eyes with gently flowing water. Do not induce vomiting. If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain an open airway and prevent aspiration. Keep patient quiet and maintain normal body temperature. Obtain medical attention. Halogenated aliphatic hydrocarbons and related compounds
Suitable extinguishing media For small (incipient) fires, use media such as "alcohol" foam, dry chemical, or carbon dioxide. For large fires, apply water from as far as possible. Use very large quantities (flooding) of water applied as a mist or spray; solid streams of water may be ineffective. Cool all affected containers with flooding quantities of water.
Highly flammable. Vapour/air mixtures are explosive.
Use powder, alcohol-resistant foam, water spray, carbon dioxide. In case of fire: keep drums, etc., cool by spraying with water.
Remove all ignition sources. Consult an expert! Personal protection: self-contained breathing apparatus. Cover the spilled material with foam. Do NOT wash away into sewer.
Remove all ignition sources. Consult an expert! Personal protection: self-contained breathing apparatus. Cover the spilled material with foam. Do NOT wash away into sewer.
ACCIDENTAL RELEASE MEASURES. Personal precautions: Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safe areas. Beware of vapors accumulating to form explosive concentrations. Vapors can accumulate in low areas.
NO open flames, NO sparks and NO smoking. Closed system, ventilation, explosion-proof electrical equipment and lighting. Do NOT use compressed air for filling, discharging, or handling. Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Fireproof. Separated from strong oxidants. Store in an area without drain or sewer access.Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Store in cool place.
TLV: 100 ppm as TWA
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear safety spectacles.
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
Use ventilation.
no data available
Liquid.
Colourless.
no data available
< -20 °C. Atm. press.:1 atm.
58 °C. Atm. press.:760 mm Hg.
Highly flammable.
no data available
-17 °C. Atm. press.:100.2 kPa.
402 °C. Atm. press.:>= 99.7 - <= 100.1 kPa.
no data available
no data available
kinematic viscosity (in mm2/s) = 0.375. Temperature:20°C.;kinematic viscosity (in mm2/s) = 0.307. Temperature:40°C.
In water, 4.36 mg/L at 25 deg C (est)
log Pow = 4.13. Temperature:25 °C.;Pow = 13 410. Temperature:25 °C.
22 kPa. Temperature:20 °C.
1 400 g/L. Temperature:20 °C.
8.5 (vs air)
no data available
On combustion, forms toxic and corrosive gases including hydrogen fluoride (see ICSC 0283). Reacts with strong oxidants strong oxidants.
no data available
The vapour is heavier than air and may travel along the ground; distant ignition possible. The vapour is heavier than air and may accumulate in lowered spaces causing a deficiency of oxygen.
no data available
Strong oxidizing agents.
When heated to decomposition it emits toxic vapors of /hydrofluorides/. 3,3,4,4,5,5,6,6-Nonafluoro-1-hexene
no data available
no data available
no data available
no data available
no data available
no data available
The substance is mildly irritating to the eyes.
no data available
No indication can be given about the rate at which a harmful concentration of this substance in the air is reached on evaporation at 20°C.
no data available
An estimated BCF of 370 was calculated in fish for perfluorobutyl ethylene(SRC), using an estimated log Kow of 4.4(1) and a regression-derived equation(2). According to a classification scheme(3), this BCF suggests the potential for bioconcentration in aquatic organisms is high(SRC), provided the compound is not metabolized by the organism(SRC).
Using a structure estimation method based on molecular connectivity indices(1), the Koc of perfluorobutyl ethylene can be estimated to be 7800(SRC). According to a classification scheme(2), this estimated Koc value suggests that perfluorobutyl ethylene is expected to be immobile in soil.
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: UN1993 (For reference only, please check.)
IMDG: UN1993 (For reference only, please check.)
IATA: UN1993 (For reference only, please check.)
ADR/RID: FLAMMABLE LIQUID, N.O.S. (For reference only, please check.)
IMDG: FLAMMABLE LIQUID, N.O.S. (For reference only, please check.)
IATA: FLAMMABLE LIQUID, N.O.S. (For reference only, please check.)
ADR/RID: 3 (For reference only, please check.)
IMDG: 3 (For reference only, please check.)
IATA: 3 (For reference only, please check.)
ADR/RID: I (For reference only, please check.)
IMDG: I (For reference only, please check.)
IATA: I (For reference only, please check.)
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available
High concentrations in the air cause a deficiency of oxygen with the risk of unconsciousness or death.Check oxygen content before entering the area.