Acute toxicity - Category 3, Oral
Hazardous to the aquatic environment, short-term (Acute) - Category Acute 1
H301 Toxic if swallowed
H400 Very toxic to aquatic life
P264 Wash ... thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P273 Avoid release to the environment.
P301+P316 IF SWALLOWED: Get emergency medical help immediately.
P321 Specific treatment (see ... on this label).
P330 Rinse mouth.
P391 Collect spillage.
P405 Store locked up.
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
no data available
Emergency and supportive measures: Maintain an open airway and assist ventilation if necessary. Administer supplemental oxygen. Treat coma, seizures, hypotension, and noncardiogenic pulmonary edema if they occur. Opiates and opioids
As with all fires, evacuate personnel to a safe area. Firefighters should use self-contained breathing equipment and protective clothing. Propoxyphene hydrochloride
no data available
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Wear approved respiratory protection, chemically compatible gloves and protective clothing. Wipe up spillage or collect spillage using a high efficiency vacuum cleaner. Avoid breathing dust. Place spillage in appropriately labelled container for disposal. Wash spill site. Propoxyphene hydrochloride
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Store in tight container as defined in the USP-NF. This material should be handled and stored per label instructions to ensure product integrity. Propoxyphene hydrochloride
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
Solid
Crystals from petroleum ether
no data available
165±3°C
444°C at 760 mmHg
no data available
no data available
130.6°C
no data available
no data available
no data available
no data available
no data available
no data available
2.02X10-6 mm Hg at 25 deg C (est)
1.038 g/cm3
no data available
no data available
no data available
Stable in solution at pH 2 to 3.5. Propoxyphene hydrochloride
no data available
no data available
no data available
When heated to decomposition it emits toxic fumes of /Nitrogen oxides/. .
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
AEROBIC: (d)-Propoxyphene was classified as non-biodegradable in sewage treatment(1).
An estimated BCF of 260 was calculated in fish for (d)-propoxyphene(SRC), using a log Kow of 4.18(1) and a regression-derived equation(2). According to a classification scheme(3), this BCF suggests the potential for bioconcentration in aquatic organisms is high(SRC).
The Koc of (d)-propoxyphene is estimated as 8.1X10+4(SRC), using a log Kow of 4.18(1) and a regression-derived equation(2). According to a classification scheme(3), this estimated Koc value suggests that (d)-propoxyphene is expected to be immobile in soil.
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: UN3249 (For reference only, please check.)
IMDG: UN3249 (For reference only, please check.)
IATA: UN3249 (For reference only, please check.)
ADR/RID: MEDICINE, SOLID, TOXIC, N.O.S. (For reference only, please check.)
IMDG: MEDICINE, SOLID, TOXIC, N.O.S. (For reference only, please check.)
IATA: MEDICINE, SOLID, TOXIC, N.O.S. (For reference only, please check.)
ADR/RID: 6.1 (For reference only, please check.)
IMDG: 6.1 (For reference only, please check.)
IATA: 6.1 (For reference only, please check.)
ADR/RID: II (For reference only, please check.)
IMDG: II (For reference only, please check.)
IATA: II (For reference only, please check.)
ADR/RID: Yes
IMDG: Yes
IATA: Yes
no data available
no data available