Skin corrosion, Sub-category 1C
Hazardous to the aquatic environment, long-term (Chronic) - Category Chronic 3
H314 Causes severe skin burns and eye damage
H412 Harmful to aquatic life with long lasting effects
P260 Do not breathe dust/fume/gas/mist/vapours/spray.
P264 Wash ... thoroughly after handling.
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...
P273 Avoid release to the environment.
P301+P330+P331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
P363 Wash contaminated clothing before reuse.
P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P316 Get emergency medical help immediately.
P321 Specific treatment (see ... on this label).
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P405 Store locked up.
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
Harmful if swallowed, inhaled, or absorbed through skin. Material is extremely destructive to tissues of mucous membrane, and upper respiratory tract, eyes and skin. Symptoms of exposure may include burning sensation, coughing, wheezing, laryngitis, shortness or breath, headache, nausea and vomiting. (USCG, 1999)
Immediate first aid: Ensure that adequate decontamination has been carried out. If patient is not breathing, start artificial respiration, preferably with a demand-valve resuscitator, bag-valve-mask device, or pocket mask, as trained. Perform CPR as necessary. Immediately flush contaminated eyes with gently flowing water. Do not induce vomiting. If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain an open airway and prevent aspiration. Keep patient quiet and maintain normal body temperature. Obtain medical attention. Organic acids and related compounds
If material on fire or involved in fire: Use water in flooding quantities as fog. Solid streams of water may be ineffective. Cool all affected containers with flooding quantities of water. Apply water from as far a distance as possible. Use "alcohol" foam, dry chemical or carbon dioxide. Use water spray to knock-down vapors..
This chemical is combustible. (NTP, 1992)
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Environmental considerations: Land spill: Dig a pit, pond, lagoon, holding area to contain liquid or solid material. /SRP: If time permits, pits, ponds, lagoons, soak holes, or holding areas should be sealed with an impermeable flexible membrane liner./ Dike surface flow using soil, sand bags, foamed polyurethane, or foamed concrete. Neutralize with agricultural lime (CaO), crushed limestone (CaCO3) or sodium bicarbonate (NaHCO3). Absorb bulk liquid with fly ash, cement powder, or commercial sorbents.
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Containers less than 1 gallon: Store in original container in areas inaccessible to children and persons unfamiliar with its proper use. Containers greater than 1 gallon: Do not contaminate water, food, feed by storage or disposal. ... Store this product in a cool, dry area, away from direct sunlight and heat../65 Disinfecting Heavy Duty Acid Bathroom Cleaner/
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
Liquid. Oily.
Colourless.
FAINT, FRUITY-ACID ODOR
16.5 °C. Atm. press.:Ca. 1 013 hPa.
237 °C. Atm. press.:1 013 mBar.
no data available
no data available
>= 132 - <= 134 °C. Atm. press.:Ca. 1 013 hPa.
> 300 °C. Atm. press.:Ca. 1 013 hPa. Remarks:No data available for pressure (assumed ca. 1013 hPa).
no data available
no data available
kinematic viscosity (in mm2/s) = 6.601. Temperature:20°C.;kinematic viscosity (in mm2/s) = 4.086. Temperature:40°C.
less than 1 mg/mL at 64° F (NTP, 1992)
log Pow = 3.05. Remarks:No data available for temperature and pH.
0.004 mm Hg. Temperature:25 °C. Remarks:0.49 Pa.
0.91 g/cm3. Temperature:20 °C.
5 (vs air)
no data available
no data available
no data available
CombustibleOCTANOIC ACID reacts exothermically to neutralize bases. Can react with active metals to form gaseous hydrogen and a metal salt. May absorb enough water from the air and dissolve sufficiently in it to corrode or dissolve iron, steel, and aluminum parts and containers. Reacts with cyanide salts or solutions of cyanide salts to generate gaseous hydrogen cyanide. Reacts exothermically with diazo compounds, dithiocarbamates, isocyanates, mercaptans, nitrides, and sulfides to generate flammable and/or toxic gases. Reacts with sulfites, nitrites, thiosulfates (to give H2S and SO3), dithionites (SO2), to generate flammable and/or toxic gases and heat. Reacts with carbonates and bicarbonates to generate a harmless gas (carbon dioxide) but still heat. Can be oxidized exothermically by strong oxidizing agents and reduced by strong reducing agents. A wide variety of products is possible. May initiate polymerization reactions or catalyze (increase the rate of) reactions among other materials.
no data available
no data available
When heated to decomposition it emits acrid smoke and irritating fumes.
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
AEROBIC: Octanoic acid reached 43, 53, 64 and 63% of its theoretical BOD after 2, 5, 10, and 30 days, respectively using a domestic sewage inoculum and an octanoic acid concn of 3.0 ppm(1). 100% decreases in initial octanoic acid concns of 0.5 mg/L and 4.3 mg/L were observed after 21 days incubation in aerobic mixed bacterial cultures obtained from trench leachate at low-level radioactive waste disposal sites in Maxey Flats, KY and West Valley, NY, respectively(2). Octanoic acid reached 60% of its theoretical oxygen demand after 5 days using a sewage seed(3). After a lag period of 2.2 days, octanoic acid present at a concn of 10,000 ppm, reached 60, 66, and 68% of its theoretical BOD after 5, 10, and 20 days, respectively using a sewage seed(4). Use of an adapted sewage seed reduced the lag period to 1.6 days, after which octanoic acid reached 60, 69, and 70% of its theoretical BOD after 5, 10, and 20 days, respectively(4). In Warburg respirometer tests using an activated sludge seed, octanoic acid, present at a concn of 500 ppm, reached 9.8, 20.4, and 32.8% of its theoretical oxygen demand after 6, 12, and 24 hours incubation, respectively(5). After 24 hours incubation, octanoic acid, present at a concn of 500 ppm, reached 5 and 59% of its theoretical oxygen demand using activated sludge inoculum from two different municipal sources(5). In a Warburg test using an activated sludge inoculum acclimated to phenol, octanoic acid, present at a concn of 500 ppm, reached 20% of its theoretical BOD after 12 hours(6). Two bacterial soil isolants were able to utilize octanoate as a growth substrate(7). A total organic carbon removal ratio of 97% was observed for octanoic acid using a non-acclimated activated sludge and an initial octanoic acid concn of 100 mg total organic carbon/L(8).
An estimated BCF of 3 was calculated in fish for octanoic acid(SRC), using a log Kow of 3.05(1) and a regression-derived equation(2). According to a classification scheme(3), this BCF suggests the potential for bioconcentration in aquatic organisms is low(SRC).
The Koc of undissociated octanoic acid is estimated as 1,100 for the free acid(SRC), using a log Kow of 3.05(1) and a regression-derived equation(2). According to a classification scheme(3), this estimated Koc value suggests that undissociated octanoic acid is expected to have low mobility in soil. The pKa of octanoic acid is 4.89(4), indicating that this compound will exist almost entirely in the anion form in the environment and anions generally do not adsorb more strongly to soils containing organic carbon and clay than their neutral counterparts(5).
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available