Eye irritation, Category 2
H319 Causes serious eye irritation
P264 Wash ... thoroughly after handling.
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
none
none
no data available
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
no data available
Immediate first aid: Ensure that adequate decontamination has been carried out. If patient is not breathing, start artificial respiration, preferably with a demand-valve resuscitator, bag-valve-mask device, or pocket mask, as trained. Perform CPR as necessary. Immediately flush contaminated eyes with gently flowing water. Do not induce vomiting. If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain an open airway and prevent aspiration. Keep patient quiet and maintain normal body temperature. Obtain medical attention. Organic acids and related compounds
Wear self-contained breathing apparatus for firefighting if necessary.
no data available
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closed containers for disposal.
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Keep container tightly closed in a dry and well-ventilated place. Storage class (TRGS 510): Non Combustible Solids.
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
DryPowder
Colorless crystals
Characteristic
-95°C(lit.)
68°C
no data available
no data available
-22°C(lit.)
644°F
no data available
pH of a 0.001% aqueous solution is 3.80, that of 0.1% solution is 2.80, and that of a 1.0% solution is 2.34
6.5 mPa.s (= cP) 50% aqueous solution at 25 deg C
In water, 55.8 g/100 g water at 20 deg C
log Kow = -1.26
3.28X10-8 mm Hg at 25 deg C (extrapolated)
1.641 g/cm3
4.6 (vs air)
no data available
no data available
Stable under recommended storage conditions.
no data available
no data available
Bases, oxidizing agents, reducing agents, alkali metals.
When heated to decomposition it emits acrid smoke and irritating fumes.
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
AEROBIC: In an aerobic closed bottle screening study using activated sludge and soil inoculum, malic acid had 5-, 15- and 30-day theoretical BODs of 68, 81 and 100% respectively(1). In a Warburg respirometer study using an activated sludge inoculum, theoretical BODs of 6.0-9.6% and 20.8-55.5% were observed over respective incubation periods of 4 and 24 hrs(2). In a Warburg respirometer study using a sewage sludge inoculum, a theoretical BOD of 47.2% was observed over an incubation period of 5 days(3). A theoretical BOD of 56.3% was observed in a standard BOD dilution test using a sewage inoculum(4). In a Warburg respirometer study using a phenol acclimated activated sludge inoculum, a theoretical BOD of 46% was observed over an incubation period of 12 hrs(5). Using C14-radio-labeled malic acid and a 1-hr incubation period, a 6.7% CO2 evolution was observed in a natural soil degradation study(6); when the soil was sterilized via autoclaving, the CO2 evolution was only 0.1%(6). DL-Malic acid, present at 100 mg/L, reached 73% of its theoretical BOD in 2 weeks using an activated sludge inoculum at 30 mg/L in the Japanese MITI test which classified the compound as readily biodegradable(7).
An estimated BCF of 3 was calculated in fish for malic acid(SRC), using a log Kow of -1.26(1) and a regression-derived equation(2). According to a classification scheme(3), this BCF suggests the potential for bioconcentration in aquatic organisms is low(SRC).
Using a structure estimation method based on molecular connectivity indices(1), the Koc of malic acid can be estimated to be 1(SRC). According to a classification scheme(2), this estimated Koc value suggests that malic acid is expected to have very high mobility in soil. The pKa values of malic acid are 3.51 and 5.03(3), indicating that this compound will exist partially in anion form in the environment and anions generally do not adsorb more strongly to soils containing organic carbon and clay than their neutral counterparts(4).
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available