Not classified.
none
none
none
none
none
no data available
Fresh air, rest.
Rinse skin with plenty of water or shower.
Rinse with plenty of water for several minutes (remove contact lenses if easily possible).
Rinse mouth.
no data available
Three mature ewes each received by intrarumenal infusion a supplement of 0, 1, 2 and 3 g Mg/d in sequence over four 10-day periods. Net Mg absorption distal to the pylorus took place down its electrochemical gradient, although the quantity absorbed remained small during the control and first infusion periods. The bulk of Mg absorption occurred before the pylorus and, during the control and first infusion periods, took place against its electrochemical gradient. The net Mg absorption proximal to the pylorus rose with declining efficiency as Mg intake was increased. It is suggested that saturation of the absorption process at this site was occurring.
In case of fire in the surroundings, use appropriate extinguishing media.
Not combustible. Gives off irritating or toxic fumes (or gases) in a fire.
In case of fire in the surroundings, use appropriate extinguishing media.
Personal protection: particulate filter respirator adapted to the airborne concentration of the substance. Sweep spilled substance into covered containers. If appropriate, moisten first to prevent dusting.
Personal protection: particulate filter respirator adapted to the airborne concentration of the substance. Sweep spilled substance into covered containers. If appropriate, moisten first to prevent dusting.
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Dry.
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear safety spectacles.
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
Use local exhaust.
no data available
Colourless, odourless, very deliquescent flakes or crystals
Thin white to gray granules and/or flakes
no data available
708°C
1412°C/1atm(lit.)
Not combustible. Gives off irritating or toxic fumes (or gases) in a fire.
no data available
no data available
no data available
no data available
no data available
no data available
Very soluble in water, freely soluble in ethanol
no data available
no data available
2.32g/mLat 25°C(lit.)
no data available
no data available
Decomposes when slowly heated to 300°C. This produces toxic and corrosive fumes including chlorine. Dissolves in water liberating a considerable amount of heat.
no data available
Decomposes when slowly heated to 300°C. This produces toxic and corrosive fumes including chlorine. Dissolves in water liberating a considerable amount of heat.
no data available
Furan-2-peroxycarboxylic acid ... explodes when heated to 30-40 deg C, or at room temp upon addition of organic or inorganic materials such as ... magnesium chloride.
When heated to decomp ... emits toxic fumes of /hydrogen chloride/.
no data available
no data available
no data available
no data available
no data available
no data available
The substance is mildly irritating to the .
no data available
A nuisance-causing concentration of airborne particles can be reached quickly when dispersed, especially if powdered.
no data available
no data available
no data available
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available