Corrosive to metals, Category 1
Skin sensitization, Category 1
Serious eye damage, Category 1
H290 May be corrosive to metals
H317 May cause an allergic skin reaction
H318 Causes serious eye damage
P234 Keep only in original packaging.
P261 Avoid breathing dust/fume/gas/mist/vapours/spray.
P272 Contaminated work clothing should not be allowed out of the workplace.
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...
P390 Absorb spillage to prevent material damage.
P302+P352 IF ON SKIN: Wash with plenty of water/...
P333+P317 If skin irritation or rash occurs: Get medical help.
P321 Specific treatment (see ... on this label).
P362+P364 Take off contaminated clothing and wash it before reuse.
P305+P354+P338 IF IN EYES: Immediately rinse with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P317 Get medical help.
P406 Store in a corrosion resistant/...container with a resistant inner liner.
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
Contact will cause severe eye and skin burns. Vapor exposure may cause eye and skin irritation. (USCG, 1999)
no data available
Fire Extinguishing Agents Not to Be Used: Avoid direct contact between water and acid. Fire Extinguishing Agents: Dry chemical, carbon dioxide or water spray. (USCG, 1999)
Excerpt from ERG Guide 153 [Substances - Toxic and/or Corrosive (Combustible)]: Combustible material: may burn but does not ignite readily. When heated, vapors may form explosive mixtures with air: indoors, outdoors and sewers explosion hazards. Those substances designated with a (P) may polymerize explosively when heated or involved in a fire. Contact with metals may evolve flammable hydrogen gas. Containers may explode when heated. Runoff may pollute waterways. Substance may be transported in a molten form. (ERG, 2016)
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Store the container tightly closed in a dry, cool and well-ventilated place. Store apart from foodstuff containers or incompatible materials.
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
Supplied as a 50% aqueous solution. Colorless to straw yellow. (USCG, 1999)
Monoclinic crystals from water
Obnoxious odor
-75°C(lit.)
122°C/19mmHg(lit.)
no data available
no data available
97°C(lit.)
no data available
no data available
no data available
no data available
Very soluble in water; slightly soluble in ethanol, ethyl ether, and benzene
log Kow= -0.07
0.0331mmHg at 25°C
1.3
no data available
no data available
No rapid reaction with air No rapid reaction with water
Forms a syrup on short exposure to air glyoxylic acid hemihydrate
GLYOXYLIC ACID is a carboxylic acid. Preparative hazard, nitric acid and glyoxal to produce glyoxylic acid has had explosive consequences. Carboxylic acids donate hydrogen ions if a base is present to accept them. They react in this way with all bases, both organic (for example, the amines) and inorganic. Their reactions with bases, called "neutralizations", are accompanied by the evolution of substantial amounts of heat. Neutralization between an acid and a base produces water plus a salt. Carboxylic acids with six or fewer carbon atoms are freely or moderately soluble in water; those with more than six carbons are slightly soluble in water. Soluble carboxylic acid dissociate to an extent in water to yield hydrogen ions. The pH of solutions of carboxylic acids is therefore less than 7.0. Many insoluble carboxylic acids react rapidly with aqueous solutions containing a chemical base and dissolve as the neutralization generates a soluble salt. Carboxylic acids in aqueous solution and liquid or molten carboxylic acids can react with active metals to form gaseous hydrogen and a metal salt. Such reactions occur in principle for solid carboxylic acids as well, but are slow if the solid acid remains dry. Even "insoluble" carboxylic acids may absorb enough water from the air and dissolve sufficiently in it to corrode or dissolve iron, steel, and aluminum parts and containers. Carboxylic acids, like other acids, react with cyanide salts to generate gaseous hydrogen cyanide. The reaction is slower for dry, solid carboxylic acids. Insoluble carboxylic acids react with solutions of cyanides to cause the release of gaseous hydrogen cyanide. Flammable and/or toxic gases and heat are generated by the reaction of carboxylic acids with diazo compounds, dithiocarbamates, isocyanates, mercaptans, nitrides, and sulfides. Carboxylic acids, especially in aqueous solution, also react with sulfites, nitrites, thiosulfates (to give H2S and SO3), dithionites (SO2), to generate flammable and/or toxic gases and heat. Their reaction with carbonates and bicarbonates generates a harmless gas (carbon dioxide) but still heat. Like other organic compounds, carboxylic acids can be oxidized by strong oxidizing agents and reduced by strong reducing agents. These reactions generate heat. A wide variety of products is possible. Like other acids, carboxylic acids may initiate polymerization reactions; like other acids, they often catalyze (increase the rate of) chemical reactions.
no data available
Deliquesces quickly and forms a syrup on short exposure to air.
When heated to decomposition it emits acrid smoke and fumes.
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
Data specific to the biodegradation of glyoxylic acid in mixed cultures were not available, although glyoxylic acid was shown to biodegrade in one pure culture study(1). As a chemical class, the aliphatic acids have been shown to biodegrade readily in biodegradation screening studies(2-4); therefore, glyoxylic acid may biodegrade readily in the environment(SRC).
An estimated BCF of 3 was calculated for glyoxylic acid(SRC), using an estimated log Kow of -1.4(SRC) and a regression-derived equation(1). According to a classification scheme(2), this BCF suggests the potential for bioconcentration in aquatic organisms is low(SRC).
Using a structure estimation method based on molecular connectivity indices(1), the Koc for glyoxylic acid can be estimated to be 1(SRC). According to a classification scheme(2), this estimated Koc value suggests that glyoxylic acid is expected to have very high mobility in soil. The pKa of glyoxylic acid is 3.3(3), which indicates that this compound will exist primarily as an anion in moist soil surfaces and anions are expected to have very high mobility in soils(SRC).
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available