Acute toxicity - Category 3, Oral
Skin irritation, Category 2
Serious eye damage, Category 1
Acute toxicity - Category 2, Inhalation
H301 Toxic if swallowed
H315 Causes skin irritation
H318 Causes serious eye damage
H330 Fatal if inhaled
P264 Wash ... thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...
P260 Do not breathe dust/fume/gas/mist/vapours/spray.
P271 Use only outdoors or in a well-ventilated area.
P284 [In case of inadequate ventilation] wear respiratory protection.
P301+P316 IF SWALLOWED: Get emergency medical help immediately.
P321 Specific treatment (see ... on this label).
P330 Rinse mouth.
P302+P352 IF ON SKIN: Wash with plenty of water/...
P332+P317 If skin irritation occurs: Get medical help.
P362+P364 Take off contaminated clothing and wash it before reuse.
P305+P354+P338 IF IN EYES: Immediately rinse with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P317 Get medical help.
P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P316 Get emergency medical help immediately.
P320 Specific treatment is urgent (see ... on this label).
P405 Store locked up.
P403+P233 Store in a well-ventilated place. Keep container tightly closed.
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
no data available
Treatment of phenothiazine overdosage generally involves symptomatic and supportive care. There is no specific antidote for phenothiazine intoxication; however, anticholinergic antiparkinsonian drugs may be useful in controlling extrapyramidal reactions associated with phenothiazine overdosage. Following acute ingestion of the drugs, the stomach should be emptied by gastric lavage and consideration also should be given to repeated doses of activated charcoal. If the patient is comatose, having seizures or a dystonic reaction, or lacks the gag reflex, gastric lavage may be performed if an endotracheal tube with cuff inflated is in place to prevent aspiration of gastric contents. Gastric lavage may be useful even several hours after the drug has been ingested, since GI motility may be greatly reduced following overdosage of phenothiazines. Induction of emesis should generally not be attempted, since a phenothiazine-induced dystonic reaction of the head or neck may result in aspiration of vomitus during emesis. Administration of a saline cathartic may be beneficial in enhancing evacuation of the drug from the GI tract, especially following ingestion of extended-release preparations (eg, Spansules). Phenothiazine General Statement
Water spray, dry chemical, carbon dioxide or foam as appropriate for surrounding fire and materials.
no data available
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Wear approved respiratory protection, chemically compatible gloves and protective clothing. Wipe up spillage or collect spillage using a high efficiency vacuum cleaner. Avoid breathing dust. Place spillage in appropriately labeled container for disposal. Wash spill site.
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Commercially available preparations of fluphenazine should be protected from light and stored at room temperature; oral preparations should be stored in tightly closed containers. Freezing of the oral solution and injections should be avoided. Slight yellowish discoloration of fluphenazine hydrochloride injection will not affect potency or efficacy, but the injection should not be used if markedly discolored or if a precipitate is present.
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
Liquid
Dark brown viscous oil
no data available
224-226 (Salt)
568.3°C at 760 mmHg
no data available
no data available
297.5°C
no data available
no data available
no data available
no data available
no data available
no data available
1.11X10-10 mm Hg at 25 deg C (est)
1.272g/cm3
no data available
no data available
no data available
Light sensitive. Fluphenazine Decanoate
no data available
no data available
Fluphenazine hydrochloride oral concentrate solution should not be mixed with beverages containing caffeine (eg, coffee, cola), tannic acid (eg, tea), or pectinates (eg, apple juice), since physical incompatibility may result.
When heated to decomposition it emits very toxic fumes of /hydrogen fluoride/, /nitroge and sulfur/ oxides.
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available