Not classified.
none
none
none
none
none
no data available
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
no data available
Immediate first aid: Ensure that adequate decontamination has been carried out. If patient is not breathing, start artificial respiration, preferably with a demand valve resuscitator, bag-valve-mask device, or pocket mask, as trained. Perform CPR if necessary. Immediately flush contaminated eyes with gently flowing water. Do not induce vomiting. If vomiting occurs, lean patient forward or place on the left side (head-down position, if possible) to maintain an open airway and prevent aspiration. Keep patient quiet and maintain normal body temperature. Obtain medical attention. Poisons A and B
Suitable extinguishing media: Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
no data available
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
ACCIDENTAL RELEASE MEASURES: Personal precautions, protective equipment and emergency procedures: Use personal protective equipment. Avoid dust formation. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Avoid breathing dust. Environmental precautions: Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided. Methods and materials for containment and cleaning up: Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closed containers for disposal.
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Keep container tightly closed in a dry and well-ventilated place.
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
Solid.
Small, colorless crystals or powder at room temperature
Odorless
116 °C.
>= 297 - <= 298 °C.
no data available
no data available
125°C(lit.)
495 °C. Remarks:No data on pressure.
no data available
no data available
no data available
In water, 8.85X10+2 mg/L at 25 deg C
log Pow = 1.59. Remarks:Room temperature.
0 hPa. Temperature:20 °C.;0 hPa. Temperature:25 °C.;0 hPa. Temperature:50 °C.
1.291 g/cm3. Temperature:20 °C.
no data available
no data available
no data available
Stable under recommended storage conditions.
no data available
no data available
Incompatible materials: Strong oxidizing agents, strong bases
When heated to decomposition it emits acrid smoke and fumes.
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
AEROBIC: Biodegradation is expected to be an important environmental fate process for this compound(SRC). A pseudo first-order rate constant of 2.07X10-3 hr-1 was measured in an aerobic screening test conducted with a phenol-acclimated sludge inoculum over a 7 day incubation period(1). This corresponds to a half-life of about 14 days(1). A rate constant of 8.27X10-3 hr-1 was measured in an aerobic screening test conducted with a cresol-acclimated sludge inoculum over a 1 day incubation period(2). This corresponds to a half-life of about 3.5 days(2). Average concentrations of not detected, 0.84, 0.05 and 0.85 ng/L were reported for ethylparaben in gray water from 32 residences and associated effluent from aerobic, anaerobic and anaerobic+aerobic biological treatment systems, respectively. Testing was done in August, 2008 in Sneek, The Netherlands(3). Ethylparaben, present at an average concentration of 880 ng/L, exhibited half-lives of 1.8 days and 27.5 hours using an activated sludge batch test and a real wastewater treatment plant test, respectively; sampling was conducted during April and May 2010 in a metropolitan area of northwest Spain(4).
An estimated BCF of 20 was calculated for ethylparaben(SRC), using a log Kow of 2.47(1) and a regression derived equation(2). According to a classification scheme(3), this BCF suggests the potential for bioconcentration in aquatic organisms is low(SRC).
Koc values of 209, 162 and 119 have been reported for acidic forest soil, agricultural soil and sediment samples obtained from Lake Constance, Germany, respectively(1). Based on a recommended classification scheme(2), these Koc values indicate that ethylparaben is expected to have high to moderate mobility in soil. The pKa of ethylparaben is 8.34(3), indicating that this compound will partially exist in anion form in the environment and anions generally do not adsorb more strongly to soils containing organic carbon and clay than their neutral counterparts(4).
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Yes
IMDG: Yes
IATA: Yes
no data available
no data available