Not classified.
none
none
none
none
none
no data available
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
no data available
Basic treatment: Establish a patent airway (oropharyngeal or nasopharyngeal airway, if needed). Suction if necessary. Watch for signs of respiratory insufficiency and assist ventilations if necessary. Administer oxygen by nonrebreather mask at 10 to 15 L/min. Anticipate seizures, minimize external stimuli, and treat if necessary . For eye contamination, flush eyes immediately with water. Irrigate each eye continuously with 0.9% saline (NS) during transport . Do not use emetics. For ingestion, rinse mouth and administer 5 ml/kg up to 200 ml of water for dilution if the patient can swallow, has a strong gag reflex, and does not drool. Administer activated charcoal . Chlordane and related compounds
Use dry chemical, carbon dioxide or alcohol-resistant foam.
no data available
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Store the container tightly closed in a dry, cool and well-ventilated place. Store apart from foodstuff containers or incompatible materials.
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
Solid. Powder.
White.
Odorless
350°C
599.8°C at 760 mmHg
no data available
no data available
311.3°C
Ca. 370 °C. Remarks:At atm. press. of ca.101325.0 Pa.
no data available
no data available
no data available
Soluble in o-dichlorobenzene
log Kow = 11.6
1.03E-13mmHg at 25°C
> 1.706 - < 1.713 g/cm3. Temperature:20 °C.
no data available
no data available
no data available
Stable in water.
no data available
no data available
no data available
When heated to decomposition it emits toxic fumes of /hydrogen chloride/.
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
AEROBIC: Dechlorane plus, present at 100 mg/l, reached 0.6% of its theoretical BOD in 2 weeks using an activated sludge inoculum at 30 mg/l and the Japanese MITI test(1). Nominal dechlorane plus concentrations of 0.01, 1, 10 and 100 mg/l in water inoculated with sewage sludge remained unchanged after 21 days(2). C-14 labeled dechlorane plus was not degraded within 2 weeks in an aerobic biodegradation test using a sewage sludge inoculum(2). Some degradation was reported after 6 weeks. The concentration of the test substance was not specified. No oxygen utilization was detected after 21 days during a closed bottle test using a sewage sludge inoculum(2). The initial concentration of dechlorane plus was 4 mg/l. Based on these screening test results, biodegradation of dechlorane plus is expected to be very slow in the environment.
A BCF range of 14-121 was measured using orange-red killifish (Oryzias latipes) which were exposed over an 8-week period(1). According to a classification scheme(2), this BCF range suggests the potential for bioconcentration in aquatic organisms is low to high(SRC), provided the compound is not metabolized by the organism(SRC). The concentration of dechlorane plus measured in archived fish (walleye) from Lake Erie was 0.14-0.91 ng/g lipid weight indicating that this substance is at least partially biologically available(3).
The Koc of dechlorane plus is estimated as 4.9X10+7(SRC), using a water solubility of 4.4X10-8 mg/l(1) and a regression-derived equation(2). According to a classification scheme(3), this estimated Koc value suggests that dechlorane plus is expected to be immobile in soil.
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available