Pyrophoric liquids, Category 1
Substances and mixtures, which in contact with water, emit flammable gases, Category 1
Skin corrosion, Sub-category 1B
Hazardous to the aquatic environment, short-term (Acute) - Category Acute 1
Hazardous to the aquatic environment, long-term (Chronic) - Category Chronic 1
H250 Catches fire spontaneously if exposed to air
H260 In contact with water releases flammable gases which may ignite spontaneously
H314 Causes severe skin burns and eye damage
H410 Very toxic to aquatic life with long lasting effects
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P222 Do not allow contact with air.
P233 Keep container tightly closed.
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...
P231+P232 Handle and store contents under inert gas/....Protect from moisture.
P223 Do not allow contact with water.
P260 Do not breathe dust/fume/gas/mist/vapours/spray.
P264 Wash ... thoroughly after handling.
P273 Avoid release to the environment.
P302+P334 IF ON SKIN: Immerse in cool water or wrap in wet bandages.
P370+P378 In case of fire: Use ... to extinguish.
P302+P335+P334 IF ON SKIN: Brush off loose particles from skin. Immerse in cool water [or wrap in wet bandages].
P301+P330+P331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
P363 Wash contaminated clothing before reuse.
P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P316 Get emergency medical help immediately.
P321 Specific treatment (see ... on this label).
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P391 Collect spillage.
P402+P404 Store in a dry place. Store in a closed container.
P405 Store locked up.
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
Inhalation of mist or vapor causes immediate irritation of nose and throat; excessive or prolonged inhalation of fumes from ignition or decomposition may cause ``metal fume fever'' (sore throat, headache, fever, chills, nausea, vomiting, muscular aches, perspiration, constricting sensation in lungs, weakness, sometimes prostration); symptoms usually last 12-24 hrs., with complete recovery in 24-48 hrs. Eyes are immediately and severely irritated on contact with liquid, vapor, or dilute solution; without thorough irrigation, cornea may be permanently damaged. Moisture in skin combines with chemical to cause thermal and acid burns; tissue may be scarred without prompt treatment. Ingestion is unlikely but would cause immediate burns at site of contact; pain, nausea, vomiting, cramps, and diarrhea may follow; if untreated, tissue may become ulcerated. (USCG, 1999)
no data available
Do not use water. use dry chem to extinguish fire. where access to the area is strictly controlled, it may be best to allow the release to burn spontaneously. fight fire from protected location or maximum possible distance.
Special Hazards of Combustion Products: Yields zinc oxide fumes when burning; can cause ``metal fume fever'' (see 5.2) Behavior in Fire: Reacts spontaneously with air or oxygen, and violently with water, evolving flammable ethane gas. Contact with water applied to adjacent fires will intensify the fire. (USCG, 1999)
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Store in a cool, dry, well-ventilated location. Separate from air, water, oxidizing materials, organic peroxides, flammable materials. Keep material under carbon dioxide, nitrogen, or other inert gas.
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
Diethylzinc is a pyrophoric liquid with a garlic-like odor. It is stable when it is shipped in sealed tubes with carbon dioxide. It may decompose violently in water and ignite spontaneously with air. It is toxic by ingestion. If exposed to heat or flame, containers of this material may explode. It is used as an aircraft fuel.
MOBILE LIQUID
Garlic-like odor
273°C(lit.)
117°C(lit.)
no data available
no data available
-23°C
0° F (USCG, 1999)
no data available
no data available
0.682 cP at 70 deg F
MISCIBLE WITH ETHER, PETROLEUM ETHER, BENZENE, HYDROCARBONS
no data available
20.8 mm Hg @ 25 deg C
0.726g/mLat 25°C
no data available
no data available
Highly flammable. Ignites in air with a blue flame giving off a peculiar garlic-like odor, [Merck, 11th ed., 1989]. Diethyl zinc is spontaneously flammable in air, [Douda(1966)]. Reacts violently with water to form flammable ethane gas, [Brauer(1965)].
Stable in sealed tube & carbon dioxide
IGNITES IN ... CHLORINE.DIETHYLZINC is pyrophoric in air, it ignites instantaneously. It reacts explosively with alcohols (methanol, ethanol), bromine, chlorine or liquefied sulfur dioxide [Houben-Weyl, 1973, 13.2a, p. 855, 757, 709]. Reaction with water, nitro compounds, arsenic trichloride, phosphorus trichloride is violent [Bretherick, 5th ed., 1995, p. 587].
no data available
Reacts violently with bromine, water, nitro compounds. ... Reacts violently with nonmetal halides (e.g., arsenic trichloride or phosphorus trichloride to produce pyrophoric triethyl arsine or triethyl phosphine).
When heated to decomp ... emits toxic fumes of /zinc oxide/.
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: UN3394 (For reference only, please check.)
IMDG: UN3394 (For reference only, please check.)
IATA: UN3394 (For reference only, please check.)
ADR/RID: ORGANOMETALLIC SUBSTANCE, LIQUID, PYROPHORIC, WATER- REACTIVE (For reference only, please check.)
IMDG: ORGANOMETALLIC SUBSTANCE, LIQUID, PYROPHORIC, WATER- REACTIVE (For reference only, please check.)
IATA: ORGANOMETALLIC SUBSTANCE, LIQUID, PYROPHORIC, WATER- REACTIVE (For reference only, please check.)
ADR/RID: 4.2 (For reference only, please check.)
IMDG: 4.2 (For reference only, please check.)
IATA: 4.2 (For reference only, please check.)
ADR/RID: I (For reference only, please check.)
IMDG: I (For reference only, please check.)
IATA: I (For reference only, please check.)
ADR/RID: Yes
IMDG: Yes
IATA: Yes
no data available
no data available