Organic peroxides, Type C
Skin irritation, Category 2
Skin sensitization, Category 1
Serious eye damage, Category 1
H242 Heating may cause a fire
H315 Causes skin irritation
H317 May cause an allergic skin reaction
H318 Causes serious eye damage
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P234 Keep only in original packaging.
P235 Keep cool.
P240 Ground and bond container and receiving equipment.
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...
P264 Wash ... thoroughly after handling.
P261 Avoid breathing dust/fume/gas/mist/vapours/spray.
P272 Contaminated work clothing should not be allowed out of the workplace.
P370+P378 In case of fire: Use ... to extinguish.
P302+P352 IF ON SKIN: Wash with plenty of water/...
P321 Specific treatment (see ... on this label).
P332+P317 If skin irritation occurs: Get medical help.
P362+P364 Take off contaminated clothing and wash it before reuse.
P333+P317 If skin irritation or rash occurs: Get medical help.
P305+P354+P338 IF IN EYES: Immediately rinse with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P317 Get medical help.
P403 Store in a well-ventilated place.
P410 Protect from sunlight.
P411 Store at temperatures not exceeding …°C/…°F.
P420 Store separately.
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
Excerpt from ERG Guide 148 [Organic Peroxides (Heat and Contamination Sensitive / Temperature Controlled)]: Fire may produce irritating, corrosive and/or toxic gases. Ingestion or contact (skin, eyes) with substance may cause severe injury or burns. Runoff from fire control or dilution water may cause pollution. (ERG, 2016)
no data available
Excerpt from ERG Guide 148 [Organic Peroxides (Heat and Contamination Sensitive / Temperature Controlled)]: The temperature of the substance must be maintained at or below the "Control Temperature" at all times. SMALL FIRE: Water spray or fog is preferred; if water not available use dry chemical, CO2 or regular foam. LARGE FIRE: Flood fire area with water from a distance. Use water spray or fog; do not use straight streams. Do not move cargo or vehicle if cargo has been exposed to heat. Move containers from fire area if you can do it without risk. FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. BEWARE OF POSSIBLE CONTAINER EXPLOSION. ALWAYS stay away from tanks engulfed in fire. For massive fire, use unmanned hose holders or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2016)
Excerpt from ERG Guide 148 [Organic Peroxides (Heat and Contamination Sensitive / Temperature Controlled)]: May explode from heat, contamination or loss of temperature control. These materials are particularly sensitive to temperature rises. Above a given "Control Temperature" they decompose violently and catch fire. May ignite combustibles (wood, paper, oil, clothing, etc.). May ignite spontaneously if exposed to air. May be ignited by heat, sparks or flames. May burn rapidly with flare-burning effect. Containers may explode when heated. Runoff may create fire or explosion hazard. (ERG, 2016)
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Store the container tightly closed in a dry, cool and well-ventilated place. Store apart from foodstuff containers or incompatible materials.
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
Liquid. Refrigerated liquid.
Colourless.
no data available
>= -68.5 - <= -66 °C. Remarks:The test item PEROXAN EPC S showed a melting range, no melting point.
186.2 °C. Atm. press.:101.325 kPa. Remarks:Handbook data, no further details reported.
no data available
no data available
160.2°C
no data available
no data available
no data available
dynamic viscosity (in mPa s) = 40. Temperature:0.0°C. Remarks:Mean value of three measurement.
In water: 880 mg/L. Temperature:25 °C. Remarks:PH is not reported (WSKOW v1.42, EPISuite, US EPA).
log Pow = 6.97. Remarks:Log Pow was estimated using EPISuite.
> 0 - < 0.001 Pa. Temperature:Ca. 25 °C. Remarks:In the range of 0,00001 to 0,001 Pa; below 0,01 Pa.
0.98 g/ml. Temperature:0 °C.
no data available
no data available
No rapid reaction with air. No rapid reaction with water.
no data available
DI-(2-ETHYLHEXYL) PEROXYDICARBONATE decomposes violently or explosively at temperatures 0-10° C. owing to self-accelerating exothermic decomposition; Several explosions were due to shock, heat or friction; amines and certain metals can cause accelerated decomposition [Bretherick, 1979 p. 156], Danger of explosion when dry
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: UN3119 (For reference only, please check.)
IMDG: UN3119 (For reference only, please check.)
IATA: UN3119 (For reference only, please check.)
ADR/RID: ORGANIC PEROXIDE TYPE F, LIQUID, TEMPERATURE CONTROLLED (For reference only, please check.)
IMDG: ORGANIC PEROXIDE TYPE F, LIQUID, TEMPERATURE CONTROLLED (For reference only, please check.)
IATA: ORGANIC PEROXIDE TYPE F, LIQUID, TEMPERATURE CONTROLLED (For reference only, please check.)
ADR/RID: 5.2 (For reference only, please check.)
IMDG: 5.2 (For reference only, please check.)
IATA: 5.2 (For reference only, please check.)
ADR/RID: (For reference only, please check.)
IMDG: (For reference only, please check.)
IATA: (For reference only, please check.)
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available