Acute toxicity - Category 4, Oral
H302 Harmful if swallowed
P264 Wash ... thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P301+P317 IF SWALLOWED: Get medical help.
P330 Rinse mouth.
none
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
no data available
In the presence of hypoventilation or apnea, oxygen should be administered and respiration should be assisted or controlled as indicated. A patent airway must be maintained; an oropharyngeal airway or endotracheal tube might be indicated. The patient should be carefully observed for 24 hours; body warmth and adequate fluid intake should be maintained. If hypotension occurs and is severe or persists, the possibility of hypovolemia should be considered and managed with appropriate parenteral fluid therapy. If significant extrapyramidal reactions occur in the context of an overdose, an anticholinergic should be administered.
As with all fires, evacuate personnel to a safe area. Firefighters should use self-contained breathing equipment and protective clothing.
no data available
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Wear approved respiratory protection, chemically compatible gloves, and protective clothing. Wipe up spillage or collect spillage using a high-efficiency vacuum cleaner. Avoid breathing dust. Place spillage in appropriately labeled container for disposal. Wash spill site.
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Commercially available droperidol injection should be protected from light and stored at room temperature (15-25 deg C).
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
Solid
White to light tan, amorphous or microcrystalline powder
Odorless
148-149°C
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
33.4 [ug/mL]
no data available
2.02X10-11 mm Hg at 25 deg C (est)
1.269g/cm3
no data available
no data available
no data available
Sensitive to light, air & heat
no data available
no data available
Droperidol injection is physically and/or chemically incompatible with some drugs (e.g., parenteral barbiturates), but the compatibility depends on several factors (e.g., concentrations of the drugs, specific diluents used, resulting pH, temperature). Specialized references should be consulted for specific compatibility information.
When heated to decomposition it emits very toxic fumes of /fluoride and oxides of nitrogen/..
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
An estimated BCF of 25 was calculated in fish for droperidol(SRC), using a log Kow of 3.50(1) and a regression-derived equation(2). According to a classification scheme(3), this BCF suggests the potential for bioconcentration in aquatic organisms is low(SRC).
The Koc of droperidol is estimated as 820(SRC), using a log Kow of 3.50(1) and a regression-derived equation(2). According to a classification scheme(3), this estimated Koc value suggests that droperidol is expected to have low mobility in soil. The pKa of droperidol is 7.46(4), indicating that this compound will exist partially in the cation form in the environment and cations generally adsorb more strongly to soils containing organic carbon and clay than their neutral counterparts(5).
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: UN3249 (For reference only, please check.)
IMDG: UN3249 (For reference only, please check.)
IATA: UN3249 (For reference only, please check.)
ADR/RID: MEDICINE, SOLID, TOXIC, N.O.S. (For reference only, please check.)
IMDG: MEDICINE, SOLID, TOXIC, N.O.S. (For reference only, please check.)
IATA: MEDICINE, SOLID, TOXIC, N.O.S. (For reference only, please check.)
ADR/RID: 6.1 (For reference only, please check.)
IMDG: 6.1 (For reference only, please check.)
IATA: 6.1 (For reference only, please check.)
ADR/RID: II (For reference only, please check.)
IMDG: II (For reference only, please check.)
IATA: II (For reference only, please check.)
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available