Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
no data available
Maintain open airway and assist ventilation if necessary. Treat agitation, seizures, coma, and hypothermia if they occur. Continually monitor temperature, other vital signs, and the ECG for a minimum of 6 hours. Hypertension is best treated with parenteral vasodilator such as phentolamine or nitroprusside. Treat tachyarrhythmias with propranolol or esmolol. Treat arterial vasospasm /with/ nitroglycerin sublingually ... /or/ iv. Intracoronary artery nitroglycerin may be required if there is no response to intravenous infusion. Also consider using a calcium antagonist. Amphetamines
Use dry chemical, carbon dioxide or alcohol-resistant foam.
no data available
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Diethylpropion hydrochloride is hygroscopic and Should be protected from moisture; . ... Commercially available diethylpropion hydrochloride tablets and extended-release tablets should be stored in tight containers at room temperature, preferably at a temperature less than 30 deg C. Diethylpropion hydrochloride
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
Solid
no data available
no data available
no data available
292°C
no data available
no data available
95°C
no data available
no data available
no data available
no data available
In water, 1.1X10+3 mg/L at 25 deg C (est)
no data available
2.1X10-3 mm Hg at 25 deg C (est)
0.972
no data available
no data available
no data available
Stable in dry air Diethylpropion hydrochloride
no data available
no data available
no data available
When heated to decomp it emits very toxic fumes of /hydrogen chloride and nitrogen oxides./ Diethylpropion hydrochloride
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
An estimated BCF of 6 was calculated for diethylpropion(SRC), using an estimated log Kow of 3.0(1) and a regression-derived equation(2). According to a classification scheme(3), this BCF suggests the potential for bioconcentration in aquatic organisms is low(SRC).
Using a structure estimation method based on molecular connectivity indices(1), the Koc of diethylpropion can be estimated to be 680(SRC). According to a classification scheme(2), this estimated Koc value suggests that diethylpropion is expected to have low mobility in soil. The estimated pKa of diethylpropion is 8.2(3), indicating that this compound will primarily exist in the cation form in the environment and cations generally adsorb more strongly to soils containing organic carbon and clay than their neutral counterparts(4).
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available