Flammable gases, Category 1A, Flammable gas
H220 Extremely flammable gas
H280 Contains gas under pressure; may explode if heated
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P377 Leaking gas fire: Do not extinguish, unless leak can be stopped safely.
P381 In case of leakage, eliminate all ignition sources.
P403 Store in a well-ventilated place.
none
no data available
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
no data available
no data available
If material on fire or involved in fire: Do not extinguish fire unless flow can be stopped. Use water in flooding quantities as fog. Cool all affected containers with flooding quantities of water. Apply water from as far a distance as possible.
no data available
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Never use cylinders of deuterium in areas where flames, excessive heat or sparks may occur. Utilize only explosion proof equipment and spark proof tools in areas where deuterium is handled.
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
no data available
COLORLESS GAS
Odorless
-259.2°C(lit.)
-252.8°C(lit.)
no data available
LOWER: 5%; UPPER: 75% (% BY VOLUME)
no data available
1085 DEG F
no data available
no data available
no data available
SLIGHTLY SOL IN COLD WATER
no data available
17.14 kPa
0.07 (21°C. vs air)
no data available
no data available
no data available
no data available
Very dangerous fire and explosion hazard when exposed to heat, flame, sparks and oxidizers.
no data available
Explosive when mixed with air, oxygen ... hydrogen
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: UN1049 (For reference only, please check.)
IMDG: UN1049 (For reference only, please check.)
IATA: UN1049 (For reference only, please check.)
ADR/RID: HYDROGEN, COMPRESSED (For reference only, please check.)
IMDG: HYDROGEN, COMPRESSED (For reference only, please check.)
IATA: HYDROGEN, COMPRESSED (For reference only, please check.)
ADR/RID: 2.1 (For reference only, please check.)
IMDG: 2.1 (For reference only, please check.)
IATA: 2.1 (For reference only, please check.)
ADR/RID: (For reference only, please check.)
IMDG: (For reference only, please check.)
IATA: (For reference only, please check.)
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available