Hazardous to the aquatic environment, short-term (Acute) - Category Acute 1
Hazardous to the aquatic environment, long-term (Chronic) - Category Chronic 1
H410 Very toxic to aquatic life with long lasting effects
P273 Avoid release to the environment.
P391 Collect spillage.
none
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Fresh air, rest.
Remove contaminated clothes. Rinse and then wash skin with water and soap.
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.
Rinse mouth.
no data available
Emergency and supportive measures: Treat bronchospasm and anaphylaxis if they occur. Observe patients with a history of large ingestions for at least 4-6 hours for any signs of CNS depression or seizures. Pyrethrins and pyrethroids
Use carbon dioxide, foam, or dry chemical /on fires involving pyrethroids/. Pyrethrum
no data available
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Do NOT wash away into sewer. Do NOT let this chemical enter the environment. Collect leaking and spilled liquid in sealable containers as far as possible. Absorb remaining liquid in sand or inert absorbent. Then store and dispose of according to local regulations.
SRP: Wastewater from contaminant suppression, cleaning of protective clothing/equipment, or contaminated sites should be contained and evaluated for subject chemical or decomposition product concentrations. Concentrations shall be lower than applicable environmental discharge or disposal criteria. Alternatively, pretreatment and/or discharge to a POTW is acceptable only after review by the governing authority. Due consideration shall be given to remediation worker exposure (inhalation, dermal and ingestion) as well as fate during treatment, transfer and disposal. If it is not practicable to manage the chemical in this fashion, it must meet Hazardous Material Criteria for disposal.
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Provision to contain effluent from fire extinguishing. Separated from food and feedstuffs. Keep in a well-ventilated room.Ventilate well. Store in closed drum in cool, dry place.
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
PALE YELLOW-TO-YELLOW-BROWN LIQUID.
Colorless liquid
Faint characteristic odor
no data available
437°C at 760 mmHg
Combustible. Liquid formulations containing organic solvents may be flammable.
no data available
186.6°C
no data available
no data available
pH = 5.16 at 20 deg C
no data available
Soluble in xylene and acetone
log Kow = 7.54 (est)
0mmHg at 25°C
1.12 g/cm3
no data available
no data available
no data available
Stable under irradiation, in most organic solvents, and on inorganic mineral diluents.
Combustible. Liquid formulations containing organic solvents may be flammable.
no data available
Incompatible with alkaline materials.
When heated to decomposition it emits acrid smoke and fumes. (+)-cis,trans-Phenothrin
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
AEROBIC: Although environmental biodegradation data specific to phenothrin were not available(SRC, 2009), the pyrethroid class of insecticides is readily degraded by environmental microorganisms(1,2). Residues of trans-phenothrin fell to <10 ppb (initial concentration not specified) within 45 days in an aerobic soil(2). Pyrethroids are metabolized by both hydrolytic and oxidative processes(2).
An estimated BCF of 230 was calculated for phenothrin(SRC), using a log Kow of 6.01(1) and a regression-derived equation(2). According to a classification scheme(3), this BCF suggests the potential for bioconcentration in aquatic organisms is high, provide the compound is not metabolized by the organism(SRC).
The Koc of phenothrin is estimated as 1.2X10+5(SRC), using a log Kow of 6.01(1) and a regression-derived equation(2). According to a classification scheme(3), this estimated Koc value suggests that phenothrin is expected to be immobile in soil.
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: Yes
IMDG: Yes
IATA: Yes
no data available
no data available