Hazardous to the aquatic environment, long-term (Chronic) - Category Chronic 2
H411 Toxic to aquatic life with long lasting effects
P273 Avoid release to the environment.
P391 Collect spillage.
none
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
no data available
Basic Treatment: Establish a patent airway (oropharyngeal or nasopharyngeal airway, if needed). Suction if necessary. Encourage patient to take deep breaths. Watch for signs of respiratory insufficiency and assist ventilations if necessary. Administer oxygen by nonrebreather mask at 10 to 15 L/min. Monitor for pulmonary edema and treat if necessary . Monitor for shock and treat if necessary . Anticipate seizures and treat if necessary . For eye contamination, flush eyes immediately with water. Irrigate each eye continuously with 0.9% saline (NS) during transport . Do not use emetics. For ingestion, rinse mouth and administer 5 ml/kg up to 200 ml of water for dilution if the patient can swallow, has a strong gag reflex, and does not drool . Irritating materials
Dry chemical, foam or carbon dioxide
no data available
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
For minor spills, leaks, etc., follow all precautions indicated on /the product/ label and clean up immediately. Take special care to avoid contamination of equipment and facilities during cleanup procedures and disposal of wastes. Technical cyromazine
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Do not contaminate water, food, or feed by storage or disposal practices. Store in a cool, dry place. Do not store this product under wet conditions. Technical cyromazine
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
white crystals
Colorless crystals
no data available
132°C(lit.)
235°C(lit.)
no data available
no data available
126°C(lit.)
no data available
no data available
no data available
no data available
All in g/kg, 20 deg C: In methanol 22, isopropanol, 2.5, acetone, 1.7, n-octanol 1.2, dichloromethane 0.25, toluene, 0.015, hexane 0.0002
log Kow = -0.06 (pH 7.0)
3.36X10-9 mm Hg at 25 deg C
1.622 g/cm3
no data available
no data available
no data available
No hydrolysis was observed < or = 70 deg C for 28 days. Stable <310 deg C.
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
Cancer Classification: Group E Evidence of Non-carcinogenicity for humans
no data available
no data available
no data available
no data available
Numerous studies conducted (laboratory and field) demonstrate the cyromazine is degraded by biological mechanisms(1); no rates or additional data were available(SRC).
An estimated BCF of 3 was calculated in fish for cyromazine(SRC), using an experimental log Kow of -0.06(1) and a regression-derived equation(2). According to a classification scheme(3), this BCF suggests the potential for bioconcentration in aquatic organisms is low(SRC).
Based upon a variety of measured Koc values in different soils (range of 81 to 1,800), cyromazine has a recommended Koc of 765(1). According to a classification scheme(2), this recommended Koc value suggests that cyromazine is expected to have low mobility in soil. Cyromazine has also been reported to have moderate mobility in soil(3), which would correspond to the lower Koc values measured in some soils(SRC). An agricultural runoff study(4) found that cyromazine (applied to soil via chicken manure) was present in runoff waters with concentrations increasing as rainfall rates increased. Anilines (aromatic amines) are expected to bind strongly to humus or organic matter in soils due to the high reactivity of the aromatic amino group(5,6), suggesting that mobility may be much lower than predicted in some soils(SRC).
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: UN2810 (For reference only, please check.)
IMDG: UN2810 (For reference only, please check.)
IATA: UN2810 (For reference only, please check.)
ADR/RID: TOXIC LIQUID, ORGANIC, N.O.S. (For reference only, please check.)
IMDG: TOXIC LIQUID, ORGANIC, N.O.S. (For reference only, please check.)
IATA: TOXIC LIQUID, ORGANIC, N.O.S. (For reference only, please check.)
ADR/RID: 6.1 (For reference only, please check.)
IMDG: 6.1 (For reference only, please check.)
IATA: 6.1 (For reference only, please check.)
ADR/RID: I (For reference only, please check.)
IMDG: I (For reference only, please check.)
IATA: I (For reference only, please check.)
ADR/RID: Yes
IMDG: Yes
IATA: Yes
no data available
no data available