Eye irritation, Category 2
Reproductive toxicity, Additional category for effects on or via lactation
H319 Causes serious eye irritation
H362 May cause harm to breast-fed children
P264 Wash ... thoroughly after handling.
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...
P203 Obtain, read and follow all safety instructions before use.
P260 Do not breathe dust/fume/gas/mist/vapours/spray.
P263 Avoid contact during pregnancy and while nursing.
P270 Do not eat, drink or smoke when using this product.
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P318 IF exposed or concerned, get medical advice.
none
none
no data available
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
no data available
Emergency and supportive measures: Maintain an open airway and assist ventilation if necessary. Treat coma, seizures, hypotension, anaphylaxis, and hemolysis if they occur. Replace fluid losses resulting from gastroenteritis with intravenous crystalloids. Antibacterial agents
As with all fires, evacuate personnel to a safe area. Firefighters should use self-contained breathing equipment and protective clothing.
no data available
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Wear approved respiratory protection, chemically compatible gloves, and protective clothing. Wipe up spillage or collect spillage using a high-efficiency vacuum cleaner. Avoid breathing dust. Place spillage in appropriately labeled container for disposal. Wash spill site.
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Store in tight container as defined in the USP-NF. This material should be handled and stored per label instructions to ensure product integrity.
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
Solid
Yellow, amorphous solid
no data available
141 - 143°C
628.1°C at 760 mmHg
no data available
no data available
no data available
no data available
no data available
no data available
no data available
>63.7 [ug/mL]
no data available
2.07E-18mmHg at 25°C
1.29 g/cm3
no data available
no data available
no data available
Stable in air & light. hcl
no data available
no data available
no data available
When heated to decomposition it emits toxic fumes of /chlorine, oxides of sulfur, and oxides of nitrogen/.
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
AEROBIC: Clindamycin, present at an average concentration of 3.03 mg/L, exhibited -2% (due to oxygen consumption in the blank) and 3% theoretical BOD in 14 and 28 days, respectively, using an activated sludge inoculum incubated in the dark at 20 deg C as per OECD 301 D, the Closed Bottle test(1). Clindamycin, present at 3000 ng/g biosolids which were generated in waste water treatment processes from a plant in Oregon, OH in 2007, exhibited a degradation rate constant of 0.012/day, half-life of 58 days when stored under aerobic field conditions. Experiments were conducted out-of-doors starting August 13, 2007 and lasting 77 days; background concentration of clindamycin in the biosolids was 23.2 ng/g. Rapid loss was observed in the first 2 days, followed by a long-term stable phase, indicating the influence of nonreversible sorption due to its cationic form(2).
An estimated BCF of 12 was calculated in fish for clindamycin(SRC), using a log Kow of 2.16(1) and a regression-derived equation(2). According to a classification scheme(3), this BCF suggests the potential for bioconcentration in aquatic organisms is low(SRC),
Using a structure estimation method based on molecular connectivity indices(1), the Koc of clindamycin can be estimated to be 70(SRC). According to a classification scheme(2), this estimated Koc value suggests that clindamycin is expected to have high mobility in soil. However, the pKa of clindamycin is 7.79(3), indicating that this compound will exist partially in the cation form in the environment and cations generally adsorb more strongly to soils containing organic carbon and clay than their neutral counterparts(4).
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available