Acute toxicity - Category 2, Oral
H300 Fatal if swallowed
P264 Wash ... thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P301+P316 IF SWALLOWED: Get emergency medical help immediately.
P321 Specific treatment (see ... on this label).
P330 Rinse mouth.
P405 Store locked up.
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
Highly toxic by mouth. (EPA, 1998)
Atropine sulfate injection is used as an antidote to the systemic effects of carbachol.
Excerpt from ERG Guide 154 [Substances - Toxic and/or Corrosive (Non-Combustible)]: SMALL FIRE: Dry chemical, CO2 or water spray. LARGE FIRE: Dry chemical, CO2, alcohol-resistant foam or water spray. Move containers from fire area if you can do it without risk. Dike fire-control water for later disposal; do not scatter the material. FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Do not get water inside containers. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks engulfed in fire. (ERG, 2016)
When heated to decomposition, it emits very toxic fumes of chloride and nitrogen oxides. The aqueous solution is stable even when heated. (EPA, 1998)
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Store in airtight containers. Protect from light.
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
Prismatic crystals or powder. Odorless, but develops a faint odor of aliphatic amine upon standing in an open container. Cholinergic, parasympathomimetic, used chiefly in large animals, especially for colic in the horse. (EPA, 1998)
Hard prismatic crystals
Odorless or has a slight amine-like odor
13°C(lit.)
173°C/24mmHg(lit.)
no data available
no data available
90°C(lit.)
no data available
no data available
Neutral to litmus (aqueous soln)
no data available
no data available
no data available
115 mmHg
1.93
no data available
no data available
no data available
The aqueous soln is stable even when heated.
CARBACHOL CHLORIDE is a carbamate ester. Carbamates are chemically similar to, but more reactive than amides. Like amides they form polymers such as polyurethane resins. Carbamates are incompatible with strong acids and bases, and especially incompatible with strong reducing agents such as hydrides. Flammable gaseous hydrogen is produced by the combination of active metals or nitrides with carbamates. Strongly oxidizing acids, peroxides, and hydroperoxides are incompatible with carbamates.
no data available
STABILITY: This chemical is sensitive to light (may discolor). Solutions of this chemical in water, DMSO, 95% ethanol or acetone should be stable for 24 hours under normal lab conditions.REACTIVITY: This chemical is incompatible with strong bases and strong oxidizing agents. It is also incompatible with active metals, calcium, aluminum, magnesium, zinc and their alloys. This chemical will attack some forms of plastics, rubber and coatings. (NTP, 1992)
When heated to decomposition it emits ... very toxic fumes of /hydrogen chloride, ammonia and nitrogen oxides/.
no data available
no data available
no data available
no data available
EPA-D
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: UN2811 (For reference only, please check.)
IMDG: UN2811 (For reference only, please check.)
IATA: UN2811 (For reference only, please check.)
ADR/RID: TOXIC SOLID, ORGANIC, N.O.S. (For reference only, please check.)
IMDG: TOXIC SOLID, ORGANIC, N.O.S. (For reference only, please check.)
IATA: TOXIC SOLID, ORGANIC, N.O.S. (For reference only, please check.)
ADR/RID: 6.1 (For reference only, please check.)
IMDG: 6.1 (For reference only, please check.)
IATA: 6.1 (For reference only, please check.)
ADR/RID: I (For reference only, please check.)
IMDG: I (For reference only, please check.)
IATA: I (For reference only, please check.)
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available