Acute toxicity - Category 2, Oral
H300 Fatal if swallowed
P264 Wash ... thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P301+P316 IF SWALLOWED: Get emergency medical help immediately.
P321 Specific treatment (see ... on this label).
P330 Rinse mouth.
P405 Store locked up.
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
Super toxic; probable oral lethal dose in humans is less than 5 mg/kg or less than 7 drops for a 70 kg (150 lb.) person. May cause serious central nervous system damage leading to convulsions. (EPA, 1998)
Control seizures. Seizure activity from these compounds may be so severe that doses necessary for seizure control may paralyze respiration. For this reason, it is best to intubate the trachea as early as possible in the course of seizure control and support pulmonary ventilation mechanically. This has the added advantage of protecting the airway from aspiration of regurgitated gastric contents. ... For seizure management, most patients respond well to usual management consisting of benzodiazepines, or phenytoin and phenobarbital. Convulsants
This chemical is a noncombustible solid. Use dry chemical, carbon dioxide, water spray, or alcohol foam extinguishers. Poisonous gases are produced in fire including chloride fumes and nitrogen oxides. If material or contaminated runoff enters waterways, notify downstream users of potentially contaminated waters. Notify local health and fire officials and pollution control agencies. From a secure, explosion-proof location, use water spray to cool exposed containers. If cooling streams are ineffective (venting sound increases in volume and pitch, tank discolors, or shows any signs of deforming), withdraw immediately to a secure position...
It emits highly toxic chloride fumes when heated to decomposition. Avoid acids and acid fumes. Very stable in neutral medium. Avoid decomposing heat. (EPA, 1998)
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Spill Handling: Evacuate and restrict persons not wearing protective equipment from area of spill or leak until cleanup is complete. Remove all ignition sources. Use organic vapor respiratory protection. Stay upwind; keep out of low areas. Wear self-contained (positive pressure if available) breathing apparatus and full protective clothing. Do not touch spilled material; stop leak if you can do so without risk. Small spills: absorb with sand or other noncombustible absorbent material and place into containers for later disposal. Small dry spills: with clean shovel place material into clean, dry container and cover; move containers from spill area. Large spills: dike far ahead of spill for later disposal. If water pollution occurs, notify appropriate authorities. Ventilate area of spill or leak. It may be necessary to contain and dispose of this chemical as a hazardous waste. If material or contaminated runoff enters waterways, notify downstream users of potentially contaminated waters...
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Castrix must be stored to avoid contact with strong acids (such as hydrochloric, sulfuric and nitric) and acid fumes since violent reactions occur. Store in tightly closed containers in a cool, well-ventilated area.
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
Crimidine is a brown waxy solid or colorless crystals. Used as a rodenticide. Not registered as a pesticide in the U.S. (EPA, 1998)
Colorless crystals
no data available
87°C
291.2°C at 760mmHg
no data available
no data available
129.9°C
no data available
no data available
no data available
no data available
Very soluble in ethanol
log Kow = 1.31 (est)
Less than 10-5 at 68F (EPA, 1998)
1.207g/cm3
no data available
no data available
No rapid reaction with air. No rapid reaction with water.
Very stable in neutral media, but decomposed by strong acids and alkalis.
CRIMIDINE neutralizes acids in exothermic reactions to form salts plus water. May be incompatible with isocyanates, halogenated organics, peroxides, phenols (acidic), epoxides, anhydrides, and acid halides. Flammable gaseous hydrogen may be generated in combination with strong reducing agents, such as hydrides.
no data available
no data available
When heated to decomposition it emits very toxic fumes of hydrogen chloride and nitrogen oxides.
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
An estimated BCF of 2 was calculated for crimidine(SRC), using an estimated log Kow of 1.31(1) and a regression-derived equation(2). According to a classification scheme(3), this BCF suggests the potential for bioconcentration in aquatic organisms is low(SRC).
Using a structure estimation method based on molecular connectivity indices(1), the Koc for crimidine can be estimated to be 22(SRC). According to a classification scheme(2), this estimated Koc value suggests that crimidine is expected to have very high mobility in soil(SRC).
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: UN2761 (For reference only, please check.)
IMDG: UN2761 (For reference only, please check.)
IATA: UN2761 (For reference only, please check.)
ADR/RID: ORGANOCHLORINE PESTICIDE, SOLID, TOXIC (For reference only, please check.)
IMDG: ORGANOCHLORINE PESTICIDE, SOLID, TOXIC (For reference only, please check.)
IATA: ORGANOCHLORINE PESTICIDE, SOLID, TOXIC (For reference only, please check.)
ADR/RID: 6.1 (For reference only, please check.)
IMDG: 6.1 (For reference only, please check.)
IATA: 6.1 (For reference only, please check.)
ADR/RID: I (For reference only, please check.)
IMDG: I (For reference only, please check.)
IATA: I (For reference only, please check.)
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available