Acute toxicity - Category 3, Oral
Acute toxicity - Category 3, Dermal
Acute toxicity - Category 1, Inhalation
H301 Toxic if swallowed
H311 Toxic in contact with skin
H330 Fatal if inhaled
P264 Wash ... thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...
P260 Do not breathe dust/fume/gas/mist/vapours/spray.
P271 Use only outdoors or in a well-ventilated area.
P284 [In case of inadequate ventilation] wear respiratory protection.
P301+P316 IF SWALLOWED: Get emergency medical help immediately.
P321 Specific treatment (see ... on this label).
P330 Rinse mouth.
P302+P352 IF ON SKIN: Wash with plenty of water/...
P316 Get emergency medical help immediately.
P361+P364 Take off immediately all contaminated clothing and wash it before reuse.
P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P320 Specific treatment is urgent (see ... on this label).
P405 Store locked up.
P403+P233 Store in a well-ventilated place. Keep container tightly closed.
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
Poisonous. May be fatal if inhaled, swallowed, or absorbed through skin. Contact may cause burns to skin and eyes. (EPA, 1998)
no data available
Keep unnecessary people away; isolate hazard area and deny entry. Stay upwind; keep out of low areas. Ventilate closed spaces before entering them. Wear positive pressure breathing apparatus and special protective clothing. Remove and isolate contaminated clothing at the site. Small fires: dry chemical, carbon dioxide, water spray, or foam. Large fires: water spray, fog, or foam. Move container from fire area if you can do it without risk. Fight fire from maximum distance. Dike fire control water for later disposal; do not scatter the material. (EPA, 1998)
When heated to decomposition, it emits very toxic fumes of cyanide and nitrogen oxides. Container may explode in heat of fire. Runoff from fire control water may give off poisonous gases. Avoid sodium hypochlorite. (EPA, 1998)
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Store the container tightly closed in a dry, cool and well-ventilated place. Store apart from foodstuff containers or incompatible materials.
Component | Phenylacetonitrile | |||
---|---|---|---|---|
CAS No. | 140-29-4 | |||
Limit value - Eight hours | Limit value - Short term | |||
ppm | mg/m3 | ppm | mg/m3 | |
Latvia | ? | 0,8 | ? | ? |
Remarks |
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
Phenylacetonitrile, liquid is a colorless oily liquid with an aromatic odor. Insoluble in water and slightly denser than water. Contact may irritate skin, eyes, and mucous membranes. May be toxic by ingestion. Used to make other chemicals.
Colorless oily liquid
Aromatic odor
-24°C(lit.)
230°C
no data available
no data available
101°C(lit.)
no data available
no data available
no data available
no data available
less than 1 mg/mL at 63° F (NTP, 1992)
log Kow = 1.56
0.1 mm Hg ( 20 °C)
1.01
no data available
no data available
This chemical is moisture sensitive. Insoluble in water.
no data available
PHENYLACETONITRILE can react with strong acids, strong bases, strong oxidizing agents and strong reducing agents. It may react vigorously with sodium hypochlorite. (NTP, 1992).
no data available
Explosive reaction with sodium hypochlorite.
When heated to decomposition it emits very toxic fumes of /hydrogen cyanide and nitrogen oxides/.
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
AEROBIC: Benzyl cyanide, present at 100 mg/L, reached 77% of its theoretical BOD in 2 weeks using an activated sludge inoculum at 30 mg/L and the Japanese MITI test(1). This indicates rapid biodegradation is likely in the environment.
An estimated BCF of 9 was calculated for benzyl cyanide(SRC), using a log Kow of 1.56(1) and a regression-derived equation(2). According to a classification scheme(3), this BCF suggests the potential for bioconcentration in aquatic organisms is low(SRC), provided the compound is not metabolized by the organism(SRP).
The Koc of benzyl cyanide is estimated as 170(SRC), using a log Kow of 1.56(1) and a regression-derived equation(2). According to a classification scheme(3), this estimated Koc value suggests that benzyl cyanide is expected to have moderate mobility in soil.
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: UN2470 (For reference only, please check.)
IMDG: UN2470 (For reference only, please check.)
IATA: UN2470 (For reference only, please check.)
ADR/RID: PHENYLACETONITRILE, LIQUID (For reference only, please check.)
IMDG: PHENYLACETONITRILE, LIQUID (For reference only, please check.)
IATA: PHENYLACETONITRILE, LIQUID (For reference only, please check.)
ADR/RID: 6.1 (For reference only, please check.)
IMDG: 6.1 (For reference only, please check.)
IATA: 6.1 (For reference only, please check.)
ADR/RID: III (For reference only, please check.)
IMDG: III (For reference only, please check.)
IATA: III (For reference only, please check.)
ADR/RID: No
IMDG: No
IATA: No
no data available