Not classified.
H280 Contains gas under pressure; may explode if heated
none
none
none
none
no data available
Fresh air, rest. Artificial respiration may be needed. Refer for medical attention.
ON FROSTBITE: rinse with plenty of water, do NOT remove clothes. Refer for medical attention .
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
Excerpt from ERG Guide 121 [Gases - Inert]: Vapors may cause dizziness or asphyxiation without warning. Vapors from liquefied gas are initially heavier than air and spread along ground. (ERG, 2016)
Excerpt from ERG Guide 120 [Gases - Inert (Including Refrigerated Liquids)]: Vapors may cause dizziness or asphyxiation without warning. Vapors from liquefied gas are initially heavier than air and spread along ground. Contact with gas or liquefied gas may cause burns, severe injury and/or frostbite. (ERG, 2016)
Immediate first aid: Ensure that adequate decontamination has been carried out. If patient is not breathing, start artificial respiration, preferably with a demand-valve resuscitator, bag-valve-mask device, or pocket mask, as trained. Perform CPR as necessary. Immediately flush contaminated eyes with gently flowing water. Do not induce vomiting. If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain an open airway and prevent aspiration. Keep patient quiet and maintain normal body temperature. Obtain medical attention. Simple asphyxiants and related compounds
If material involved in fire: Extinguish fire using agent suitable for type of surrounding fire. Material itself does not burn or burns with difficulty. Cool all affected containers with flooding quantities of water. Apply water from as far a distance as possible. Argon, compressed; Argon, refrigerated liquid
Excerpt from ERG Guide 121 [Gases - Inert]: Non-flammable gases. Containers may explode when heated. Ruptured cylinders may rocket. (ERG, 2016)
Excerpt from ERG Guide 120 [Gases - Inert (Including Refrigerated Liquids)]: Non-flammable gases. Containers may explode when heated. Ruptured cylinders may rocket. (ERG, 2016)
In case of fire in the surroundings, use appropriate extinguishing media.
Personal protection: self-contained breathing apparatus. Ventilation. NEVER direct water jet on liquid.
Personal protection: self-contained breathing apparatus. Ventilation. NEVER direct water jet on liquid.
Personal precautions: Avoid breathing vapors, mist or gas. Environmental precautions: No special environmental precautions required. Methods for cleaning up: Wipe up with absorbent material (e.g. cloth, fleece).
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Fireproof if in building. Keep in a well-ventilated room.Keep container tightly closed in a dry and well-ventilated place. Contents under pressure.
Component | Argon | |||
---|---|---|---|---|
CAS No. | 7440-37-1 | |||
Limit value - Eight hours | Limit value - Short term | |||
ppm | mg/m3 | ppm | mg/m3 | |
Canada - Ontario | (1) | ? | ? | ? |
New Zealand | (1) | ? | ? | ? |
Remarks | ||||
Canada - Ontario | (1) Simple asphyxiant | |||
New Zealand | (1) Simple asphyxiant |
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear safety goggles or face shield.
Cold-insulating gloves. Protective clothing.
Use ventilation.
no data available
Argon is a colorless odorless noncombustible gas. Heavier than air and can asphyxiate by displacement of air. Exposure of the container to prolonged heat or fire can cause it to rupture violently and rocket . If liquefied, contact of the very cold liquid with water may cause violent boiling. If the water is hot, there is the possibility that a liquid "superheat" explosion may occur. Contacts with water in a closed container may cause dangerous pressure to build.
Colorless monatomic gas
Odorless
-189°C
-185.7°C(lit.)
Not combustible. Heating will cause rise in pressure with risk of bursting.
no data available
no data available
no data available
no data available
no data available
no data available
Soluble in organic liquids
0.74
no data available
1.784(0°C)
1.38 (21 °C, vs air)
no data available
No rapid reaction with air. No rapid reaction with water.
no data available
The gas is heavier than air and may accumulate in lowered spaces causing a deficiency of oxygen.These substances undergo no chemical reactions under any known circumstances. They are nonflammable, noncombustible and nontoxic. They can asphyxiate.
no data available
CHEMICAL PROFILE: Contact of very cold liquefied gas with water may result in vigorous or violent boiling of the product and extremely rapid vaporization due to the large temperature differences involved. If the water is hot, there is the possibility that a liquid "superheat" explosion may occur. Pressures may build to dangerous levels if liquid gas contacts water in a closed container (Handling Chemicals Safely 1980). (REACTIVITY, 1999)
no data available
no data available
no data available
no data available
no data available
no data available
no data available
Asphyxiation. The liquid may cause frostbite.
no data available
On loss of containment this substance can cause suffocation by lowering the oxygen content of the air in confined areas.
no data available
no data available
no data available
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: UN1951 (For reference only, please check.)
IMDG: UN1951 (For reference only, please check.)
IATA: UN1951 (For reference only, please check.)
ADR/RID: ARGON, REFRIGERATED LIQUID (For reference only, please check.)
IMDG: ARGON, REFRIGERATED LIQUID (For reference only, please check.)
IATA: ARGON, REFRIGERATED LIQUID (For reference only, please check.)
ADR/RID: 2.2 (For reference only, please check.)
IMDG: 2.2 (For reference only, please check.)
IATA: 2.2 (For reference only, please check.)
ADR/RID: (For reference only, please check.)
IMDG: (For reference only, please check.)
IATA: (For reference only, please check.)
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available
Other UN number: 1006 Argon, compressed.High concentrations in the air cause a deficiency of oxygen with the risk of unconsciousness or death.Check oxygen content before entering area.