Flammable liquids, Category 3
Eye irritation, Category 2
Specific target organ toxicity – single exposure, Category 3
H226 Flammable liquid and vapour
H319 Causes serious eye irritation
H335 May cause respiratory irritation
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P233 Keep container tightly closed.
P240 Ground and bond container and receiving equipment.
P241 Use explosion-proof [electrical/ventilating/lighting/...] equipment.
P242 Use non-sparking tools.
P243 Take action to prevent static discharges.
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...
P264 Wash ... thoroughly after handling.
P261 Avoid breathing dust/fume/gas/mist/vapours/spray.
P271 Use only outdoors or in a well-ventilated area.
P303+P361+P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse affected areas with water [or shower].
P370+P378 In case of fire: Use ... to extinguish.
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P319 Get medical help if you feel unwell.
P403+P235 Store in a well-ventilated place. Keep cool.
P403+P233 Store in a well-ventilated place. Keep container tightly closed.
P405 Store locked up.
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Fresh air, rest. Refer for medical attention.
Remove contaminated clothes. Rinse skin with plenty of water or shower.
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.
Rinse mouth. Give one or two glasses of water to drink. Refer for medical attention .
no data available
no data available
Use water spray, powder, foam, carbon dioxide.
Flammable. Above 43°C explosive vapour/air mixtures may be formed.
Use water spray, powder, foam, carbon dioxide. In case of fire: keep cylinder cool by spraying with water.
Personal protection: filter respirator for organic gases and vapours adapted to the airborne concentration of the substance. Ventilation. Remove all ignition sources. Collect leaking and spilled liquid in sealable containers as far as possible. Absorb remaining liquid in sand or inert absorbent. Then store and dispose of according to local regulations. Do NOT wash away into sewer.
Personal protection: filter respirator for organic gases and vapours adapted to the airborne concentration of the substance. Ventilation. Remove all ignition sources. Collect leaking and spilled liquid in sealable containers as far as possible. Absorb remaining liquid in sand or inert absorbent. Then store and dispose of according to local regulations. Do NOT wash away into sewer.
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
NO open flames, NO sparks and NO smoking. Above 43°C use a closed system, ventilation and explosion-proof electrical equipment. Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Fireproof. Separated from strong oxidants, strong bases and strong reducing agents. Well closed.
TLV: 10 ppm as TWA.MAK: 53 mg/m3, 10 ppm; peak limitation category: I(2); pregnancy risk group: D.EU-OEL: 53 mg/m3, 10 ppm as TWA; 107 mg/m3, 20 ppm as STEL
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear safety spectacles.
Protective gloves.
Use ventilation, local exhaust or breathing protection.
no data available
Liquid.
Colorless.
no data available
-57 °C. Remarks:Experimental conditions not reported.
159 °C. Remarks:Experimental conditions not reported.
Class II Combustible Liquid: Fl.P. at or above 100°F and below 140°F.
no data available
46 °C.
413 °C. Atm. press.:98 675 Pa. Remarks:Main study: Third experiment.;409 °C. Atm. press.:99 423 Pa. Remarks:Main study: Second experiment.;411 °C. Atm. press.:99 476 Pa. Remarks:Main study: First experiment.
no data available
no data available
0.848. Temperature:20°C. Remarks:Standard deviation 0.004 mPa s.
in water, g/100ml at 20°C: 0.3
log Pow = 1.98. Temperature:25 °C. Remarks:PH not reported.
270 Pa. Temperature:25 °C.
0.822 g/cm3. Temperature:20 °C.
(air = 1): 4.4
no data available
Reacts with oxidants, strong reducing agents and strong bases. This generates fire hazard.
no data available
The vapour is heavier than air and may travel along the ground; distant ignition possible.
no data available
Strong oxidizers
no data available
no data available
no data available
no data available
no data available
no data available
no data available
The substance is irritating to the eyes, skin and respiratory tract. The substance may cause effects on the central nervous system. Exposure far above the OEL could cause unconsciousness.
The substance defats the skin, which may cause dryness or cracking.
A harmful contamination of the air will be reached rather slowly on evaporation of this substance at 20°C.
no data available
no data available
no data available
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: UN2271 (For reference only, please check.)
IMDG: UN2271 (For reference only, please check.)
IATA: UN2271 (For reference only, please check.)
ADR/RID: ETHYL AMYL KETONE (For reference only, please check.)
IMDG: ETHYL AMYL KETONE (For reference only, please check.)
IATA: ETHYL AMYL KETONE (For reference only, please check.)
ADR/RID: 3 (For reference only, please check.)
IMDG: 3 (For reference only, please check.)
IATA: 3 (For reference only, please check.)
ADR/RID: III (For reference only, please check.)
IMDG: III (For reference only, please check.)
IATA: III (For reference only, please check.)
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available
Explosive limits are unknown in literature, although the substance is flammable and has a flash point <61°C.The odour warning when the exposure limit value is exceeded is insufficient.