Acute toxicity - Category 4, Oral
Acute toxicity - Category 4, Inhalation
H302 Harmful if swallowed
H332 Harmful if inhaled
P264 Wash ... thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P261 Avoid breathing dust/fume/gas/mist/vapours/spray.
P271 Use only outdoors or in a well-ventilated area.
P301+P317 IF SWALLOWED: Get medical help.
P330 Rinse mouth.
P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P317 Get medical help.
none
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
no data available
Basic treatment: Establish a patent airway. Suction if necessary. Watch for signs of respiratory insufficiency and assist ventilations if needed. Administer oxygen by nonrebreather mask at 10 to 15 L/min. Monitor for pulmonary edema and treat if necessary . Monitor for shock and treat if necessary . Anticipate seizures and treat if necessary . For eye contamination, flush eyes immediately with water. Irrigate each eye continuously with normal saline during transport . Do not use emetics. For ingestion, rinse mouth and administer 5 ml/kg up to 200 ml of water for dilution if the patient can swallow, has a strong gag reflex, and does not drool . Cover skin burns with dry sterile dressings after decontamination . Poison A and B
Use dry chemical, carbon dioxide or alcohol-resistant foam.
no data available
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Store the container tightly closed in a dry, cool and well-ventilated place. Store apart from foodstuff containers or incompatible materials.
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
clear, colorless liquid
no data available
no data available
-1°C(lit.)
87°C/25mmHg(lit.)
no data available
no data available
63°C
no data available
no data available
no data available
no data available
Insol in water
no data available
0.646mmHg at 25°C
1.09g/mLat 25°C(lit.)
no data available
no data available
no data available
no data available
A flammable liquid. Chlorostyrene
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
Data regarding the biodegradation of m-chlorostyrene in either soil or aquatic systems were not available. (SRC)
An estimated BCF of 100 was calculated for m-chlorostyrene(SRC), using an estimated log Kow of 3.54(1) and a regression-derived equation(2). According to a classification scheme(3), this BCF suggests the potential for bioconcentration in aquatic organisms is moderate(SRC).
Using a structure estimation method based on molecular connectivity indices(1), the Koc for m-chlorostyrene can be estimated to be 840(SRC). According to a classification scheme(2), this estimated Koc value suggests that m-chlorostyrene is expected to have low mobility in soil(SRC).
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: UN2263 (For reference only, please check.)
IMDG: UN2263 (For reference only, please check.)
IATA: UN2263 (For reference only, please check.)
ADR/RID: DIMETHYLCYCLOHEXANES (For reference only, please check.)
IMDG: DIMETHYLCYCLOHEXANES (For reference only, please check.)
IATA: DIMETHYLCYCLOHEXANES (For reference only, please check.)
ADR/RID: 3 (For reference only, please check.)
IMDG: 3 (For reference only, please check.)
IATA: 3 (For reference only, please check.)
ADR/RID: II (For reference only, please check.)
IMDG: II (For reference only, please check.)
IATA: II (For reference only, please check.)
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available