Flammable liquids, Category 3
Acute toxicity - Category 4, Inhalation
Specific target organ toxicity – single exposure, Category 3
H226 Flammable liquid and vapour
H332 Harmful if inhaled
H335 May cause respiratory irritation
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P233 Keep container tightly closed.
P240 Ground and bond container and receiving equipment.
P241 Use explosion-proof [electrical/ventilating/lighting/...] equipment.
P242 Use non-sparking tools.
P243 Take action to prevent static discharges.
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...
P261 Avoid breathing dust/fume/gas/mist/vapours/spray.
P271 Use only outdoors or in a well-ventilated area.
P303+P361+P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse affected areas with water [or shower].
P370+P378 In case of fire: Use ... to extinguish.
P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P317 Get medical help.
P319 Get medical help if you feel unwell.
P403+P235 Store in a well-ventilated place. Keep cool.
P403+P233 Store in a well-ventilated place. Keep container tightly closed.
P405 Store locked up.
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Fresh air, rest. Refer for medical attention.
Remove contaminated clothes. Rinse skin with plenty of water or shower. Seek medical attention if you feel unwell.
Rinse with plenty of water (remove contact lenses if easily possible). Refer for medical attention.
Rinse mouth. Do NOT induce vomiting. Refer immediately for medical attention.
no data available
no data available
Use alcohol-resistant foam, powder, carbon dioxide.
Flammable. Above 33°C explosive vapour/air mixtures may be formed.
Use powder, alcohol-resistant foam, water spray, carbon dioxide. In case of fire: keep drums, etc., cool by spraying with water.
Remove all ignition sources. Personal protection: filter respirator for organic gases and particulates adapted to the airborne concentration of the substance. Collect leaking liquid in sealable containers. Absorb remaining liquid in sand or inert absorbent. Then store and dispose of according to local regulations.
Remove all ignition sources. Personal protection: filter respirator for organic gases and particulates adapted to the airborne concentration of the substance. Collect leaking liquid in sealable containers. Absorb remaining liquid in sand or inert absorbent. Then store and dispose of according to local regulations.
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
NO open flames, NO sparks and NO smoking. Above 33°C use a closed system, ventilation and explosion-proof electrical equipment. Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Fireproof. Separated from strong oxidants.
MAK: 73 mg/m3, 20 ppm; peak limitation category: I(2); pregnancy risk group: C
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear safety goggles or eye protection in combination with breathing protection.
Protective gloves.
Use ventilation, local exhaust or breathing protection.
no data available
Liquid
no data available
no data available
252°C(lit.)
118°C
Class IC Flammable Liquid: Fl.P. at or above 73°F and below 100°F.
no data available
34°C(lit.)
360°C
no data available
no data available
8.13 mm2/s at 20°C
44.6 mg/mL at 25 °C
1.19
kPa at 20°C: 0.8
0.812
3 (vs air)
no data available
Reacts violently with oxidants.
Reacts violently with oxidants.
no data available
No data.Reacts violently with oxidants.
no data available
Strong oxidizers
no data available
no data available
no data available
no data available
no data available
no data available
no data available
The substance is irritating to the eyes and respiratory tract. If swallowed the substance may cause vomiting and could result in aspiration pneumonitis. The substance may cause effects on the central nervous system. Exposure at high levels could cause lowering of consciousness.
Repeated or prolonged contact with skin may cause dermatitis.
A harmful contamination of the air can be reached rather quickly on evaporation of this substance at 20°C.
no data available
no data available
no data available
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: UN1105 (For reference only, please check.)
IMDG: UN1105 (For reference only, please check.)
IATA: UN1105 (For reference only, please check.)
ADR/RID: PENTANOLS (For reference only, please check.)
IMDG: PENTANOLS (For reference only, please check.)
IATA: PENTANOLS (For reference only, please check.)
ADR/RID: 3 (For reference only, please check.)
IMDG: 3 (For reference only, please check.)
IATA: 3 (For reference only, please check.)
ADR/RID: II (For reference only, please check.)
IMDG: II (For reference only, please check.)
IATA: II (For reference only, please check.)
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available
EU classification is a group classification for pentanol isomers, with the exception of those specified elsewhere in Annex I.See ICSCs 0535 and 0536.The information on this card is for the racemic mixture.CAS numbers for the optical isomers: 31087-44-2 for the R(-) and 26184-62-3 for the S(+) isomer.