Specific target organ toxicity – repeated exposure, Category 2
Hazardous to the aquatic environment, short-term (Acute) - Category Acute 1
Hazardous to the aquatic environment, long-term (Chronic) - Category Chronic 1
H373 May cause damage to organs through prolonged or repeated exposure
H410 Very toxic to aquatic life with long lasting effects
P260 Do not breathe dust/fume/gas/mist/vapours/spray.
P273 Avoid release to the environment.
P319 Get medical help if you feel unwell.
P391 Collect spillage.
none
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
no data available
Immediate first aid: Ensure that adequate decontamination has been carried out. If patient is not breathing, start artificial respiration, preferably with a demand-valve resuscitator, bag-valve-mask device, or pocket mask, as trained. Perform CPR as necessary. Immediately flush contaminated eyes with gently flowing water. Do not induce vomiting. If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain an open airway and prevent aspiration. Keep patient quiet and maintain normal body temperature. Obtain medical attention. PCBs, PBBs, PCDFs, and Related Compounds
Use dry chemical, carbon dioxide, or alcohol foam extinguishers. Vapors are heavier than air and will collect in low areas. Vapors in confined areas may explode when exposed to fire. Containers may explode in fire. Storage containers and parts of containers may rocket great distances, in many directions. If material or contaminated runoff enters waterways, notify downstream users of potentially contaminated waters. Notify local health and fire officials and pollution control agencies. From a secure, explosion-proof location, use water spray to cool exposed containers. If cooling streams are ineffective (venting sound increases in volume and pitch, tank discolors, or shows any signs of deforming), withdraw immediately to a secure position ... The only respirators recommended for fire fighting are self-contained breathing apparatuses that have full facepieces and are operated in a pressure-demand or other positive pressure mode. Polychlorinated biphenyls
no data available
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Evacuate and restrict persons not wearing protective equipment from area of spill or leak until cleanup is complete. Remove all ignition sources. Ventilate area of spill or leak. Absorb liquids in vermiculite, dry sand, earth, peat, carbon, or a similar material and deposit in sealed containers. Keep this chemical out of a confined space, such as a sewer, because of the possibility of an explosion, unless the sewer is designed to prevent the build-up of explosive concentrations. It may be necessary to contain and dispose of this chemical as a hazardous waste. If material or contaminated runoff enters waterways, notify downstream users of potentially contaminated waters. Contact your Department of Environmental Protection or your regional office of the federal EPA for specific recommendations ... Spills of one pound or more must be reported to the EPA. Polychlorinated biphenyls
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Store in tightly closed containers in a cool, well-ventilated area away from strong oxidizers (such as chlorine, bromine, and fluorine). A regulated marked area should be established where this chemical is handled, used, or stored ... Polychlorinated biphenyls
Component | 2-chlorobiphenyl |
---|---|
CAS No. | 2051-60-7 |
NIOSH considers chlorodiphenyl containing 54% chlorine to be a potential occupational carcinogen. /Aroclor 1254/ NIOSH usually recommends that occupational exposures to carcinogens be limited to the lowest feasible concentration. /Aroclor 1254/ Recommended Exposure Limit: 10 Hour Time-Weighted Average: 0.001 mg/cu m. /Aroclor 1254/ |
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
Colorless to pale-yellow, viscous liquid or solid (below 50°F) with a mild, hydrocarbon odor.
Clear oil
no data available
32-34°C
274°C at 760 mmHg
no data available
no data available
115.9°C
no data available
no data available
no data available
Saybolt sec at 37.8 deg C; 39-41 Saybolt sec at 54.4 deg C; 31-32 Saybolt sec at 98.9 deg C
Solubility in water varies because Aroclors are variable mixtures.
log Kow = >4.54
0.00928mmHg at 25°C
1.131 g/cm3
no data available
no data available
NIOSH considers chlorodiphenyl containing 54% chlorine to be a potential occupational carcinogen. Aroclor 1254
PCB's are chemically very inert and are stable to conditions of hydrolysis and oxidation in industrial use. ... Polychlorinated biphenyls
PCBs may burn but do not easily ignite. Polychlorinated biphenyls
no data available
Incompatibilities: strong oxidizers. Polychlorinated biphenyls
When heated to decomposition they emit toxic fumes of Chlorine. Polychlorinated biphenyls
no data available
no data available
no data available
no data available
Classification of carcinogenicity: 1) evidence in humans: limited; 2) evidence in animals: sufficient. Overall summary evaluation of carcinogenic risk to humans is Group 2A: The agent is probably carcinogenic to humans. Polychlorinated biphenyls; from table
no data available
no data available
no data available
no data available
AEROBIC: Aroclor 1232 had 100% reported biodegradation in screening tests utilizing BOD dilution water, settled domestic wastewater inoculum, incubated for 28 days at both 5 and 10 ppm starting concentrations(1). The chlorinated congeners in PCBs have been shown to be susceptible to reductive dechlorination by anaerobic microorganisms found in aquatic sediments(2).
BCF Catostomus commersoni (white sucker) 5,500 whole body, 30 day
Using a structure estimation method based on molecular connectivity indices(1), the Koc for a representative component of Aroclor 1232 can be estimated to be 8400(SRC). According to a classification scheme(2), this estimated Koc value suggests that Aroclor 1232 is expected to be immobile in soil. PCBs, such as Aroclor 1232, are readily adsorbed onto solids (especially organic matter) and are often immobilized in sediment, although eventual re-solution into the water column can occur(3).
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: Yes
IMDG: Yes
IATA: Yes
no data available
no data available