Product identifier

  • Product name: 2-chlorobiphenyl
  • CAS: 2051-60-7

Relevant identified uses of the substance or mixture and uses advised against

  • Relevant identified uses: For R&D use only. Not for medicinal, household or other use.
  • Uses advised against: none

Company Identification

  • Company:Chemicalbook.in
  • Address:5 vasavi Layout Basaveswara Nilayam Pragathi Nagar Hyderabad, India -500090
  • Telephone:+91 9550333722

SECTION 2: Hazards identification

Classification of the substance or mixture

Specific target organ toxicity – repeated exposure, Category 2

Hazardous to the aquatic environment, short-term (Acute) - Category Acute 1

Hazardous to the aquatic environment, long-term (Chronic) - Category Chronic 1

GHS label elements, including precautionary statements

  • Pictogram(s)
  • Signal word Warning
Hazard statement(s)

H373 May cause damage to organs through prolonged or repeated exposure

H410 Very toxic to aquatic life with long lasting effects

Precautionary statement(s)
Prevention

P260 Do not breathe dust/fume/gas/mist/vapours/spray.

P273 Avoid release to the environment.

Response

P319 Get medical help if you feel unwell.

P391 Collect spillage.

Storage

none

Disposal

P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.

Other hazards which do not result in classification

no data available

SECTION 3: Composition/information on ingredients

Substance

  • Chemical name: 2-chlorobiphenyl
  • Common names and synonyms: 2-chlorobiphenyl
  • CAS number: 2051-60-7
  • EC number: 218-125-6
  • Concentration: 100%

SECTION 4: First aid measures

Description of necessary first-aid measures

If inhaled

Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.

Following skin contact

Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.

Following eye contact

Rinse with pure water for at least 15 minutes. Consult a doctor.

Following ingestion

Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.

Most important symptoms/effects, acute and delayed

no data available

Indication of immediate medical attention and special treatment needed, if necessary

Immediate first aid: Ensure that adequate decontamination has been carried out. If patient is not breathing, start artificial respiration, preferably with a demand-valve resuscitator, bag-valve-mask device, or pocket mask, as trained. Perform CPR as necessary. Immediately flush contaminated eyes with gently flowing water. Do not induce vomiting. If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain an open airway and prevent aspiration. Keep patient quiet and maintain normal body temperature. Obtain medical attention. PCBs, PBBs, PCDFs, and Related Compounds

SECTION 5: Firefighting measures

Suitable extinguishing media

Use dry chemical, carbon dioxide, or alcohol foam extinguishers. Vapors are heavier than air and will collect in low areas. Vapors in confined areas may explode when exposed to fire. Containers may explode in fire. Storage containers and parts of containers may rocket great distances, in many directions. If material or contaminated runoff enters waterways, notify downstream users of potentially contaminated waters. Notify local health and fire officials and pollution control agencies. From a secure, explosion-proof location, use water spray to cool exposed containers. If cooling streams are ineffective (venting sound increases in volume and pitch, tank discolors, or shows any signs of deforming), withdraw immediately to a secure position ... The only respirators recommended for fire fighting are self-contained breathing apparatuses that have full facepieces and are operated in a pressure-demand or other positive pressure mode. Polychlorinated biphenyls

Specific hazards arising from the chemical

no data available

Special protective actions for fire-fighters

Wear self-contained breathing apparatus for firefighting if necessary.

SECTION 6: Accidental release measures

Personal precautions, protective equipment and emergency procedures

Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.

Environmental precautions

Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.

Methods and materials for containment and cleaning up

Evacuate and restrict persons not wearing protective equipment from area of spill or leak until cleanup is complete. Remove all ignition sources. Ventilate area of spill or leak. Absorb liquids in vermiculite, dry sand, earth, peat, carbon, or a similar material and deposit in sealed containers. Keep this chemical out of a confined space, such as a sewer, because of the possibility of an explosion, unless the sewer is designed to prevent the build-up of explosive concentrations. It may be necessary to contain and dispose of this chemical as a hazardous waste. If material or contaminated runoff enters waterways, notify downstream users of potentially contaminated waters. Contact your Department of Environmental Protection or your regional office of the federal EPA for specific recommendations ... Spills of one pound or more must be reported to the EPA. Polychlorinated biphenyls

SECTION 7: Handling and storage

Precautions for safe handling

Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.

Conditions for safe storage, including any incompatibilities

Store in tightly closed containers in a cool, well-ventilated area away from strong oxidizers (such as chlorine, bromine, and fluorine). A regulated marked area should be established where this chemical is handled, used, or stored ... Polychlorinated biphenyls

SECTION 8: Exposure controls/personal protection

Control parameters

Occupational Exposure limit values
Component 2-chlorobiphenyl
CAS No. 2051-60-7

NIOSH considers chlorodiphenyl containing 54% chlorine to be a potential occupational carcinogen. /Aroclor 1254/

NIOSH usually recommends that occupational exposures to carcinogens be limited to the lowest feasible concentration. /Aroclor 1254/

Recommended Exposure Limit: 10 Hour Time-Weighted Average: 0.001 mg/cu m. /Aroclor 1254/

Biological limit values

no data available

Appropriate engineering controls

Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.

Individual protection measures, such as personal protective equipment (PPE)

Eye/face protection

Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).

Skin protection

Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.

Respiratory protection

If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.

Thermal hazards

no data available

SECTION 9: Physical and chemical properties and safety characteristics

  • Physical state:

    Colorless to pale-yellow, viscous liquid or solid (below 50°F) with a mild, hydrocarbon odor.

  • Colour:

    Clear oil

  • Odour:

    no data available

  • Melting point/freezing point:

    32-34°C

  • Boiling point or initial boiling point and boiling range:

    274°C at 760 mmHg

  • Flammability:

    no data available

  • Lower and upper explosion limit/flammability limit:

    no data available

  • Flash point:

    115.9°C

  • Auto-ignition temperature:

    no data available

  • Decomposition temperature:

    no data available

  • pH:

    no data available

  • Kinematic viscosity:

    Saybolt sec at 37.8 deg C; 39-41 Saybolt sec at 54.4 deg C; 31-32 Saybolt sec at 98.9 deg C

  • Solubility:

    Solubility in water varies because Aroclors are variable mixtures.

  • Partition coefficient n-octanol/water:

    log Kow = >4.54

  • Vapour pressure:

    0.00928mmHg at 25°C

  • Density and/or relative density:

    1.131 g/cm3

  • Relative vapour density:

    no data available

  • Particle characteristics:

    no data available

SECTION 10: Stability and reactivity

Reactivity

NIOSH considers chlorodiphenyl containing 54% chlorine to be a potential occupational carcinogen. Aroclor 1254

Chemical stability

PCB's are chemically very inert and are stable to conditions of hydrolysis and oxidation in industrial use. ... Polychlorinated biphenyls

Possibility of hazardous reactions

PCBs may burn but do not easily ignite. Polychlorinated biphenyls

Conditions to avoid

no data available

Incompatible materials

Incompatibilities: strong oxidizers. Polychlorinated biphenyls

Hazardous decomposition products

When heated to decomposition they emit toxic fumes of Chlorine. Polychlorinated biphenyls

SECTION 11: Toxicological information

Acute toxicity

  • Oral: LD50 Rat oral 4470 mg/kg
  • Inhalation: no data available
  • Dermal: no data available

Skin corrosion/irritation

no data available

Serious eye damage/irritation

no data available

Respiratory or skin sensitization

no data available

Germ cell mutagenicity

no data available

Carcinogenicity

Classification of carcinogenicity: 1) evidence in humans: limited; 2) evidence in animals: sufficient. Overall summary evaluation of carcinogenic risk to humans is Group 2A: The agent is probably carcinogenic to humans. Polychlorinated biphenyls; from table

Reproductive toxicity

no data available

STOT-single exposure

no data available

STOT-repeated exposure

no data available

Aspiration hazard

no data available

SECTION 12: Ecological information

Toxicity

  • Toxicity to fish: no data available
  • Toxicity to daphnia and other aquatic invertebrates: EC50; Species: Daphnia magna (water flea, age <24 hr); Conditions: freshwater, static, 18 deg C, pH 7.5-8.0, hardness 44-46 mg/L CaCO3, alkalinity 40-43 mg/L CaCO3, acidity 2.4-4.0 ppm, Ca hardness 34-36 ppm; Concentration: 125 ug/L for 21 days; Effect: reproduction, general /formulated product
  • Toxicity to algae: no data available
  • Toxicity to microorganisms: no data available

Persistence and degradability

AEROBIC: Aroclor 1232 had 100% reported biodegradation in screening tests utilizing BOD dilution water, settled domestic wastewater inoculum, incubated for 28 days at both 5 and 10 ppm starting concentrations(1). The chlorinated congeners in PCBs have been shown to be susceptible to reductive dechlorination by anaerobic microorganisms found in aquatic sediments(2).

Bioaccumulative potential

BCF Catostomus commersoni (white sucker) 5,500 whole body, 30 day

Mobility in soil

Using a structure estimation method based on molecular connectivity indices(1), the Koc for a representative component of Aroclor 1232 can be estimated to be 8400(SRC). According to a classification scheme(2), this estimated Koc value suggests that Aroclor 1232 is expected to be immobile in soil. PCBs, such as Aroclor 1232, are readily adsorbed onto solids (especially organic matter) and are often immobilized in sediment, although eventual re-solution into the water column can occur(3).

Other adverse effects

no data available

SECTION 13: Disposal considerations

Disposal methods

Product

The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.

Contaminated packaging

Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.

SECTION 14: Transport information

UN Number

ADR/RID: no data available

IMDG: no data available

IATA: no data available

UN Proper Shipping Name

ADR/RID: no data available

IMDG: no data available

IATA: no data available

Transport hazard class(es)

ADR/RID: no data available

IMDG: no data available

IATA: no data available

Packing group, if applicable

ADR/RID: no data available

IMDG: no data available

IATA: no data available

Environmental hazards

ADR/RID: Yes

IMDG: Yes

IATA: Yes

Special precautions for user

no data available

Transport in bulk according to IMO instruments

no data available

SECTION 15: Regulatory information

Safety, health and environmental regulations specific for the product in question

European Inventory of Existing Commercial Chemical Substances (EINECS)
Listed.
EC Inventory
Listed.
United States Toxic Substances Control Act (TSCA) Inventory
Not Listed.
China Catalog of Hazardous chemicals 2015
Not Listed.
New Zealand Inventory of Chemicals (NZIoC)
Not Listed.
(PICCS)
Not Listed.
Vietnam National Chemical Inventory
Listed.
IECSC)
Not Listed.
Korea Existing Chemicals List (KECL)
Not Listed.

SECTION 16: Other information

Abbreviations and acronyms

  • CAS: Chemical Abstracts Service
  • ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
  • RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
  • IMDG: International Maritime Dangerous Goods
  • IATA: International Air Transportation Association
  • TWA: Time Weighted Average
  • STEL: Short term exposure limit
  • LC50: Lethal Concentration 50%
  • LD50: Lethal Dose 50%
  • EC50: Effective Concentration 50%

References

  • IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
  • HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
  • IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
  • eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
  • CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
  • ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
  • ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
  • Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
  • ECHA - European Chemicals Agency, website: https://echa.europa.eu/
Disclaimer: The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties of the product. We as supplier shall not be held liable for any