Acute toxicity - Category 4, Oral
Carcinogenicity, Category 2
Specific target organ toxicity – single exposure, Category 2
Hazardous to the aquatic environment, short-term (Acute) - Category Acute 1
Hazardous to the aquatic environment, long-term (Chronic) - Category Chronic 1
H302 Harmful if swallowed
H351 Suspected of causing cancer
H371 May cause damage to organs
H410 Very toxic to aquatic life with long lasting effects
P264 Wash ... thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P203 Obtain, read and follow all safety instructions before use.
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...
P260 Do not breathe dust/fume/gas/mist/vapours/spray.
P273 Avoid release to the environment.
P301+P317 IF SWALLOWED: Get medical help.
P330 Rinse mouth.
P318 IF exposed or concerned, get medical advice.
P308+P316 IF exposed or concerned: Get emergency medical help immediately.
P391 Collect spillage.
P405 Store locked up.
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Fresh air, rest.
Remove contaminated clothes. Rinse and then wash skin with water and soap.
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.
Rinse mouth.
no data available
Emergency and supportive measures: Treat bronchospasm and anaphylaxis if they occur. Observe patients with a history of large ingestions for at least 4-6 hours for any signs of CNS depression or seizures. Pyrethrins and pyrethroids
Use carbon dioxide, foam, or dry chemical /on fires involving pyrethroids/. Pyrethrum
no data available
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Personal protection: filter respirator for organic gases and particulates adapted to the airborne concentration of the substance. Do NOT wash away into sewer. Do NOT let this chemical enter the environment. Sweep spilled substance into covered containers. If appropriate, moisten first to prevent dusting. Carefully collect remainder. Then store and dispose of according to local regulations.
SRP: Wastewater from contaminant suppression, cleaning of protective clothing/equipment, or contaminated sites should be contained and evaluated for subject chemical or decomposition product concentrations. Concentrations shall be lower than applicable environmental discharge or disposal criteria. Alternatively, pretreatment and/or discharge to a POTW is acceptable only after review by the governing authority. Due consideration shall be given to remediation worker exposure (inhalation, dermal and ingestion) as well as fate during treatment, transfer and disposal. If it is not practicable to manage the chemical in this fashion, it must meet Hazardous Material Criteria for disposal.
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Provision to contain effluent from fire extinguishing.Ventilate well. Store in closed drum in a cool, dry place.
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
COLOURLESS CRYSTALLINE POWDER WITH CHARACTERISTIC ODOUR.
White crystalline solid
Slight pyrethrum-like odor
68-70°C
453.228°C at 760 mmHg
Combustible. Liquid formulations containing organic solvents may be flammable.
no data available
200°C
no data available
no data available
no data available
no data available
Methanol (53 g/kg), hexane (20 g/kg), xylene (1 g/kg), acetone, toluene.
log Kow = 4.73
7.1X10-6 mm Hg at 30 deg C
1.2 g/cm3
no data available
no data available
no data available
Stable under normal storage and use.
Combustible. Liquid formulations containing organic solvents may be flammable.
no data available
Incompatible with mineral carriers such as kieselguhr, acidic clays and kaolin.
When heated to decomp it emits toxic fumes of /nitrogen oxides/.
no data available
no data available
no data available
no data available
Cancer Classification: Group C Possible Human Carcinogen
no data available
no data available
no data available
no data available
AEROBIC: Although environmental biodegradation data specific to tetramethrin are not available, the pyrethroid class of insecticides is degraded readily by environmental microorganisms(1,2).
An estimated BCF of 34 was calculated for tetramethrin(SRC), using a log Kow of 4.73(1) and a regression-derived equation(2). According to a classification scheme(3), this BCF suggests the potential for bioconcentration in aquatic organisms is moderate(SRC).
The Koc of tetramethrin is estimated as 790(SRC), using a log Kow of 4.73(1) and a regression-derived equation(2). According to a classification scheme(3), this estimated Koc value suggests that tetramethrin is expected to have low mobility in soil.
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Yes
IMDG: Yes
IATA: Yes
no data available
no data available