Acute toxicity - Category 4, Oral
Acute toxicity - Category 3, Inhalation
Specific target organ toxicity – single exposure, Category 3
Germ cell mutagenicity, Category 2
Hazardous to the aquatic environment, long-term (Chronic) - Category Chronic 3
H302 Harmful if swallowed
H331 Toxic if inhaled
H335 May cause respiratory irritation
H341 Suspected of causing genetic defects
H412 Harmful to aquatic life with long lasting effects
P264 Wash ... thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P261 Avoid breathing dust/fume/gas/mist/vapours/spray.
P271 Use only outdoors or in a well-ventilated area.
P203 Obtain, read and follow all safety instructions before use.
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...
P273 Avoid release to the environment.
P301+P317 IF SWALLOWED: Get medical help.
P330 Rinse mouth.
P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P316 Get emergency medical help immediately.
P321 Specific treatment (see ... on this label).
P319 Get medical help if you feel unwell.
P318 IF exposed or concerned, get medical advice.
P403+P233 Store in a well-ventilated place. Keep container tightly closed.
P405 Store locked up.
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Fresh air, rest. Refer for medical attention.
Remove contaminated clothes. Rinse and then wash skin with water and soap.
Rinse with plenty of water for several minutes (remove contact lenses if easily possible).
Rinse mouth. Refer for medical attention .
Excerpt from ERG Guide 159 [Substances (Irritating)]: Inhalation of vapors or dust is extremely irritating. May cause burning of eyes and flow of tears. May cause coughing, difficult breathing and nausea. Brief exposure effects last only a few minutes. Exposure in an enclosed area may be very harmful. Fire will produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may cause pollution. (ERG, 2016)
no data available
Excerpt from ERG Guide 159 [Substances (Irritating)]: SMALL FIRE: Dry chemical, CO2, water spray or regular foam. LARGE FIRE: Water spray, fog or regular foam. Move containers from fire area if you can do it without risk. Dike fire-control water for later disposal; do not scatter the material. FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Do not get water inside containers. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks engulfed in fire. For massive fire, use unmanned hose holders or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2016)
Excerpt from ERG Guide 159 [Substances (Irritating)]: Some of these materials may burn, but none ignite readily. Containers may explode when heated. (ERG, 2016)
Use water spray, powder, foam, carbon dioxide. In case of fire: keep drums, etc., cool by spraying with water.
Personal protection: filter respirator for organic gases and vapours adapted to the airborne concentration of the substance. Do NOT let this chemical enter the environment. Collect leaking and spilled liquid in sealable containers as far as possible. Absorb remaining liquid in sand or inert absorbent. Then store and dispose of according to local regulations.
Personal protection: filter respirator for organic gases and vapours adapted to the airborne concentration of the substance. Do NOT let this chemical enter the environment. Collect leaking and spilled liquid in sealable containers as far as possible. Absorb remaining liquid in sand or inert absorbent. Then store and dispose of according to local regulations.
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
NO open flames, NO sparks and NO smoking. Above 57°C use a closed system, ventilation and explosion-proof electrical equipment. Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Separated from food and feedstuffs. Well closed. Store in an area without drain or sewer access.
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear safety spectacles.
Protective gloves.
Use ventilation, local exhaust or breathing protection.
no data available
Liquid.
Colourless.
no data available
-58 °C. Atm. press.:760 mm Hg.
143.3 °C. Atm. press.:760 mm Hg.
Flammable. Gives off irritating or toxic fumes (or gases) in a fire.
no data available
> 140 °C.
>= 550 °C. Remarks:It is obviously not possible to ignite 1-bromo-3-chloropropane in air.
no data available
no data available
no data available
Insoluble in water
log Pow = 2.18. Remarks:Temperature and pH are in the data source.
8.53 hPa. Temperature:20 °C.
1.597 g/cm3. Temperature:20 °C.
(air = 1): 5.4
no data available
Decomposes on burning. This produces toxic and corrosive gases including hydrogen bromide (see ICSC 0282) and hydrogen chloride (see ICSC 0163).
no data available
Halogenated aliphatic compounds, such as 1-BROMO-3-CHLOROPROPANE, are moderately or very reactive. Halogenated organics generally become less reactive as more of their hydrogen atoms are replaced with halogen atoms. Materials in this group are incompatible with strong oxidizing and reducing agents. Also, they are incompatible with many amines, nitrides, azo/diazo compounds, alkali metals, and epoxides.
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
The substance may cause effects on the central nervous system and liver. This may result in impaired functions.
no data available
No indication can be given about the rate at which a harmful concentration of this substance in the air is reached on evaporation at 20°C.
1-Bromo-3-chloropropane, inoculated with effluent from a biological waste treatment plant, reached 3% of the theoretical BOD in 5 days(1).
An estimated BCF value of 27 was calculated for 1-bromo-3-chloropropane(SRC), using a measured log Kow of 2.18(1) and a recommended regression-derived equation(2). According to a classification scheme(3), this BCF value suggests that bioconcentration in aquatic organisms is low(SRC).
The Koc of 1-bromo-3-chloropropane is estimated as approximately 63(SRC), using a measured water solubility of 2240 mg/l at 25 deg C(1) and a regression-derived equation(2,SRC). According to a recommended classification scheme(3), this estimated Koc value suggests that 1-bromo-3-chloropropane has high mobility in soil(SRC).
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: UN2688 (For reference only, please check.)
IMDG: UN2688 (For reference only, please check.)
IATA: UN2688 (For reference only, please check.)
ADR/RID: 1-BROMO-3-CHLOROPROPANE (For reference only, please check.)
IMDG: 1-BROMO-3-CHLOROPROPANE (For reference only, please check.)
IATA: 1-BROMO-3-CHLOROPROPANE (For reference only, please check.)
ADR/RID: 6.1 (For reference only, please check.)
IMDG: 6.1 (For reference only, please check.)
IATA: 6.1 (For reference only, please check.)
ADR/RID: III (For reference only, please check.)
IMDG: III (For reference only, please check.)
IATA: III (For reference only, please check.)
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available