Skin irritation, Category 2
Eye irritation, Category 2
H315 Causes skin irritation
H319 Causes serious eye irritation
P264 Wash ... thoroughly after handling.
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...
P302+P352 IF ON SKIN: Wash with plenty of water/...
P321 Specific treatment (see ... on this label).
P332+P317 If skin irritation occurs: Get medical help.
P362+P364 Take off contaminated clothing and wash it before reuse.
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
none
none
no data available
Fresh air, rest.
Rinse skin with plenty of water or shower.
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.
Rinse mouth.
no data available
no data available
Use water spray, foam, powder, carbon dioxide.
Combustible. Gives off irritating or toxic fumes (or gases) in a fire. Above 63°C explosive vapour/air mixtures may be formed.
Use water spray, foam, powder, carbon dioxide.
Collect leaking and spilled liquid in sealable containers as far as possible. Absorb remaining liquid in sand or inert absorbent. Then store and dispose of according to local regulations. Then wash away with plenty of water.
Collect leaking and spilled liquid in sealable containers as far as possible. Absorb remaining liquid in sand or inert absorbent. Then store and dispose of according to local regulations. Then wash away with plenty of water.
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
NO open flames. Above 63°C use a closed system, ventilation and explosion-proof electrical equipment. Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Keep in the dark. Separated from strong oxidants.
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear safety goggles.
Protective gloves.
Use ventilation.
no data available
Liquid.
Colourless.
no data available
< -85 °C.
171 °C. Atm. press.:1 013 hPa.
Combustible. Gives off irritating or toxic fumes (or gases) in a fire.
no data available
62.5 °C. Atm. press.:961.3 mBar.
260 °C. Atm. press.:1 013 hPa.
no data available
no data available
kinematic viscosity (in mm2/s) = 3.85. Temperature:20°C.;kinematic viscosity (in mm2/s) = 3.25. Temperature:25.0°C.
in water, g/100ml: 6 (moderate)
log Pow = 1.2. Temperature:20 °C.
1.05 mm Hg. Temperature:25 °C.
0.88 g/cm3. Temperature:20 °C.;0.87 g/cm3. Temperature:25 °C.
(air = 1): 4.55
no data available
The substance can presumably form explosive peroxides. Reacts with strong oxidants.
no data available
The substance can presumably form explosive peroxides. Reacts with strong oxidants.
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
The substance is irritating to the eyes and skin.
no data available
No indication can be given about the rate at which a harmful concentration of this substance in the air is reached on evaporation at 20°C.
no data available
no data available
no data available
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available
Check for peroxides prior to distillation; eliminate if found.